Bryant 935SB Installation, Operating And Maintenance Instruction page 38

Single-stage, upflow/horizontal ultra low nox, 35-in. tall, condensing gas furnace
Table of Contents

Advertisement

935SB: Installation, Start-up, Operating and Service Maintenance Instructions
Use 45 deg. Elbows where
Avoid short horizontal offsets with 90
possible, to ensure conden-
deg. Elbows. Short offsets can be
sate drainage.
difficult to slope and may trap con-
densate.
Fig. 53 – Near Furnace Vent Connections
Install the Vent and Combustion Air Pipes
With the furnace installed in the required position, remove the desired
knockouts from the casing. It will be necessary to remove one knockout
for the vent pipe and the other knockout for the combustion air
connection (see
Fig.
12).
Use a flat blade screwdriver and tap on the knockout on opposite sides,
where the knockout meets the casing. Fold the knockout down with duct
pliers and work the knockout back and forth until it is removed. Trim
any excess metal from the knockout with tin snips.
The vent elbow can be rotated to the required location on the casing if
necessary (see
Fig.
58). To rotate the vent elbow:
1. Loosen the clamp on the inlet of the vent elbow attached to the
inducer.
2. Rotate the vent elbow to the required position. There are rounded
notches on the vent elbow to align it with the inducer housing for
each orientation.
3. Tighten the clamp around the vent elbow. Torque the clamp to 15
lb-in. (see
Fig. 54
through
Representative drawing only, some models may vary.
UPFLOW LEFT CONFIGURATION
Representative drawing only, some models may vary.
UPFLOW RIGHT CONFIGURATION
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Slope vent pipe back to the
furnace at least ¼" per foot
Fig.
56).
A14546
Representative drawing only, some models may vary.
Fig. 54 – Upflow Configurations (Appearance may vary)
See "Notes for Venting Options"
Representative drawing only, some models may vary.
HORIZONTAL LEFT-VERTICAL VENT CONFIGURATION
A11309A
Representative drawing only, some models may vary.
HORIZONAL LEFT-LEFT VENT CONFIGURATION
A11308A
38
UPFLOW VERTICAL VENT
A11310A
A11327A
A11328A