Table 6-2:
Options for mA Output Process Variable
Process variable
Viscosity measurement
Dynamic Viscosity
Kinematic Viscosity
(1)
Referred Viscosity
Secondary Referred Viscosi-
(1)
ty
(1)
API referral
Referred Density (API)
(1)(2)
Ignition quality
Calculated Carbon Aroma-
ticity Index (CCAI)
Calculated Ignition Index
(CII)
(1) Not supported on the HFVM-R.
(2) The API referral application must be enabled and configured to report referred density at 15 °C.
6.1.2
Configure Lower Range Value (LRV) and Upper Range Value
(URV)
Display
ProLink III
Field Communicator Configure > Manual Setup > Inputs/Outputs > mA Output 1 > mA Output Settings > PV LRV
Configuration and Use Manual
(continued)
Display
DYNV
KINV
RVISC
SRVIS
RDENS
CCAI
CII
OFF-LINE MAINT > OFF-LINE CONFG > IO > CONFIG MAO 1 > 4 mA
OFF-LINE MAINT > OFF-LINE CONFG > IO > CONFIG MAO 1 > 20 mA
OFF-LINE MAINT > OFF-LINE CONFG > IO > CONFIG MAO 2 > 4 mA
OFF-LINE MAINT > OFF-LINE CONFG > IO > CONFIG MAO 2 > 20 mA
Device Tools > Configuration > I/O > Outputs > mA Output > mA Output 1 > Lower Range Value
Device Tools > Configuration > I/O > Outputs > mA Output > mA Output 1 > Upper Range Vaue
Device Tools > Configuration > I/O > Outputs > mA Output > mA Output 2 > Lower Range Value
Device Tools > Configuration > I/O > Outputs > mA Output > mA Output 2 > Upper Range Vaue
Configure > Manual Setup > Inputs/Outputs > mA Output 1 > mA Output Settings > PV URV
Configure > Manual Setup > Inputs/Outputs > mA Output 2 > mA Output Settings > SV LRV
Configure > Manual Setup > Inputs/Outputs > mA Output 2 > mA Output Settings > SV URV
Integrate the meter with the control system
Label
ProLink III
Line Dynamic Viscosity
Line Kinematic Viscosity
Referred Viscosity
Referred Viscosity (Secon-
dary)
Referred Density (API)
Calculated Carbon Aroma-
ticity Index (CCAI)
Calculated Ignition Index
(CII)
Field Communicator
Dynamic Viscosity
Kinematic Viscosity
Referred Viscosity
Referred Viscosity (Secon-
dary)
Density at Reference (API)
CCAI
Calculated Ignition Index
75