Configure The Refresh Rate Of Data Shown On The Display; Enable Or Disable Automatic Scrolling Through The Display Variables - Emerson MICRO MOTION HFVM Series Configuration And Use Manual

Heavy fuel viscosity meters
Table of Contents

Advertisement

Procedure
1.
2.
5.1.4

Configure the refresh rate of data shown on the display

Display
ProLink III
Field Communicator Configure > Manual Setup > Display > Display Behavior > Refresh Rate
Overview
You can set Refresh Rate to control how frequently data is refreshed on the display.
Procedure
Set Refresh Rate to the desired value.
The default value is 1000 milliseconds. The range is 100 milliseconds to
10,000 milliseconds (10 seconds).
5.1.5
Enable or disable automatic scrolling through the
display variables
Display
ProLink III
Field Communicator Configure > Manual Setup > Display > Display Behavior > Auto Scroll
Overview
You can configure the display to automatically scroll through the configured display
variables or to show a single display variable until the operator activates Scroll. When you
set automatic scrolling, you can also configure the length of time each display variable is
displayed.
Configuration and Use Manual
Select a variable.
Set Number of Decimal Places to the number of decimal places you want shown when
the process variable or diagnostic variable appears on the display.
For temperature and density process variables, the default value is 2 decimal places.
For all other variables, the default value is 4 decimal places. The range is 0 to 5.
Tip
The lower the precision, the greater the change must be for it to be reflected on the display.
Do not set the precision too low or too high to be useful.
OFF-LINE MAINT > OFF-LINE CONFG > DISPLAY > RATE
Device Tools > Configuration > Transmitter Display > Display Variables
OFF-LINE MAINT > OFF-LINE CONFG > DISPLAY > AUTO SCRLL
Device Tools > Configuration > Transmitter Display > General
Configure device options and preferences