Tilt Over Angle (Menu => Setup => Tilt Over Angle); Calibration (Menu => Setup => Calibration) - Honeywell ScanDome III HSDC-252 Series Operation & Programming Manual

Table of Contents

Advertisement

When the dome camera is installed near a wall or corner, panning range can be limited by
user.
3.5.5 TILT OVER ANGLE (MENU => SETUP => TILT OVER ANGLE)
This option is used to set the limit of the horizontal view angle so that the trim ring or ceiling does
not obstruct the horizontal image when zooming out (wide angle).
ON: In some installations it is desirable for the dome camera to be able to see above the
horizon. When this option is chosen, the dome will tilt up over the horizon (About 5 degrees).
When the lens is zoomed out, you can see the ceiling line. But when the lens is zoomed in,
the viewing angle is narrower, and the ceiling line disappears.
W/O BUBBLE : The tilt range of the camera is limited to see the horizon so the picture
shows part of the ceiling line.
WITH BUBBLE : The tilt range of the camera is limited to see below the horizon (- 10
degrees).
3.5.6 CALIBRATION (MENU => SETUP => CALIBRATION)
ORIGIN RESET: Calibrate the ORIGIN point.
ORIGIN POSITION MOVE : Adjust the small amount of position error from
re-installation.
Panning Range Setup
Right Limit
Left Limit
Enable
Swap Right Left
Save And Exit
View Angle Setup
Tilt Over Angle
Save And Exit
Calibration
Origin Reset
Origin Position Move
Origin Offset
Auto Calibration : OFF
Save And Exit
34
: 000.0
: 000.0
: OFF/ON
: W/O BUBBLE
: DISABLE

Advertisement

Table of Contents
loading

Table of Contents