NO
: Alarm input number
FUNC
: Priority 1~8 calls Preset(xxx),
Priority 0 supports dedicated functions like a Pattern(Pxx), Tour(Txx), Scan(Sxx).
PRI
: Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.
IN
: NO/NC - normally open /Closed, OFF - ignore
OUT
: OUT1~OUT2 - Relay out 1,2
HLD
: Alarm will be held for programmed time (01 to 255 seconds)
LATCH : ON - Shows all alarms including past alarm, OFF - Shows activated alarms only.
There are 9 levels of priority. 0 : Highest priority supports repeated/dedicated functions
like a Pattern(Pxx), Tour(Txx), Scan(Sxx). 1~8: Same level of alarm calls presets one
after the other.
Ex) Alarm 01 calls Pattern 01, After alarm 01 is released alarm 02, 03 will call preset 48
and preset 01
1. Press Menu to display the main menu on the monitor. Select the Alarm option by pushing
the Joystick up or down and push to right to enter the detail menu.
2. Select the alarm input number by pushing the Joystick up or down and select the
column you wish to setup. Selected position will be highlighted.
3. Select the Preset, Status of Input (NC/NO/OFF), and Output (OUT1~2/OFF) by pushing
the Joystick to the right or to the left.
4. To increase or decrease the preset number or to change the status or output number, twist
the Joystick clockwise or counterclockwise. In case of preset, programmed preset
number will be scrolled.
5. Locate the cursor on Save and exit and push the Joystick to the Save and exit.
Press ESC to exit the program without saving.
Alarm Setup
No Fun
Pri
In
01 P01
0
OFF OFF 001
02 048
4
OFF OFF 001
03 001
4
OFF OFF 001
04 ---
3
OFF OFF 001
05 ---
3
OFF OFF 001
06 ---
3
OFF OFF 001
07 ---
3
OFF OFF 001
08 ---
3
OFF OFF 001
Save And Exit