Daikin FTXTA30AW Service Manual page 109

Optimized heating 4
Table of Contents

Advertisement

ESIE17-19C
|
Part 5. Appendix
5.1.3.3. Set target temperature in heating (DFu4)
T
= T
+ DFu4
set
R/C,set
T
= system set temperature
set
T
= remocon set temperature
R/C,set
DFu4= offset
5.1.3.3.1 Remote controller ARC466A55
Figure 5-5: How to adjust target set temperature in heating operation - Remote controller: ARC466A55
Temp
19/08/19
|
Version 1.1
Optimized Heating 4
Temp
MODE
SC
Display
Select
"SU"
Select
MODE
Temp
Select "7"
MODE
Temp
0
1
2
3
4
MODE
Send signal to indoor unit
DISPLAY NORMAL
Adjust target set temperature
0: -2.0°C
1: -1.0°C
2: ±0 (factory setting)
3: +1.0°C
4: +2.0°C
AFTER 60 sec
5.1. Field setting
Page 109