Summary of Contents for Daikin FTXTA30A2V1BW

  • Page 1 Installation manual Split system air conditioner Installation manual English Split system air conditioner FTXTA30A2V1BW...
  • Page 2: Table Of Contents

    To connect the electrical wiring on the indoor unit..5.4.2 To connect optional accessories (wired user ▪ The full set of latest technical data is available on the Daikin interface, central user interface, etc.)......extranet (authentication required). Finishing the indoor unit installation ..........
  • Page 3: About The Unit

    FAQ, declaration of conformity and the latest version of this manual, the ceiling: visit http://www.onlinecontroller.daikineurope.com. INFORMATION ▪ Daikin Industries Czech Republic s.r.o. declares that ≥50 ≥50 the radio equipment type inside of this unit is in compliance with Directive 2014/53/EU.
  • Page 4: To Close The Front Panel

    3 Push the right arm lightly to the right to disconnect the shaft ruler wrapped in a cloth and remove 2 screws. from the shaft slot on the right side. Installation manual FTXTA30A2V1BW Split system air conditioner 3P482320-9M – 2019.04...
  • Page 5: To Re-Install The Front Grille

    The removed pipe port cover can be kept in the mounting 3 Re-install the flap. plate pocket. 4 Insert the wire harness back into the connector and secure it with the wire clamp. FTXTA30A2V1BW Installation manual Split system air conditioner 3P482320-9M – 2019.04...
  • Page 6: To Drill A Wall Hole

    ▪ Connecting the drain piping to the indoor unit To connect the piping on right-side, right-bottom, left-side or left- ▪ Checking for water leaks bottom, the pipe port cover MUST be removed. Installation manual FTXTA30A2V1BW Split system air conditioner 3P482320-9M – 2019.04...
  • Page 7: Connecting The Refrigerant Piping

    III. WARNING If the supply cord is damaged, it MUST be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. FTXTA30A2V1BW Installation manual Split system air conditioner 3P482320-9M – 2019.04...
  • Page 8: To Connect The Electrical Wiring On The Indoor Unit

    Small animals that make contact with electrical parts can cause malfunctions, smoke or fire. 2× Drain hose Installation manual FTXTA30A2V1BW Split system air conditioner 3P482320-9M – 2019.04...
  • Page 9: To Fix The Unit On The Mounting Plate

    In cooling mode: 26~28°C, in heating mode: 20~24°C. NOTICE 3 The system stops operating 3  minutes after the unit is turned NEVER operate the unit without thermistors and/or OFF. pressure sensors/switches. Burning of the compressor might result. FTXTA30A2V1BW Installation manual Split system air conditioner 3P482320-9M – 2019.04...
  • Page 10: To Perform A Test Run Using The User Interface

    2 Press simultaneously. Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). Wiring diagram The wiring diagram is delivered with the unit, located inside of the outdoor unit (bottom side of the top plate).
  • Page 11 Noise filter Printed circuit board Pushbutton ON/OFF, operation switch BZ, H*C Buzzer Capacitor AC*, CN*, E*, HA*, HE*, HL*, Connection, connector HN*, HR*, MR*_A, MR*_B, S*, U, V, W, X*A, K*R_* FTXTA30A2V1BW Installation manual Split system air conditioner 3P482320-9M – 2019.04...