Installation Overview - Trane CGWF Installation Operation & Maintenance

Scroll liquid chillers
Hide thumbs Also See for CGWF:
Table of Contents

Advertisement

Table 2
Installation Responsibility Chart for
Requirement
Trane-supplied,
Trane-installed
Rigging
Isolation
Electrical
Non-fused disconnects (optional)
Unit-mounted starter
Water piping
Pressure
Relief valves
Relief
12
General Information

Installation Overview

For convenience, Table 2 summarizes responsibilities that are typically associated
with the CGWF/CCAF chiller installation process.
CGWF/CCAF
Trane-supplied,
Field-installed
Neoprene Isolators
Temperature sensor (optional
outdoor air)
Flow switches (may be field-
supplied)
Flow switches (may be field-
supplied)
Condenser water regulating valve
(optional: may be field-supplied)
Refer to the Installation Mechanical and Installation Electrical sections of this manual
for detailed installation instructions.
Locate and maintain the loose parts, e.g. isolators, flow sensors or other factory-
ordered, field-installed options, for installation, as required. Loose parts are
located in the starter/control panel.
Install the unit on a foundation with flat support surfaces, level within 1/4" (6.35
mm) and of sufficient strength to support concentrated loading. Place the manu-
facturer-supplied neoprene isolators assemblies under the unit.
Install the unit per the instructions outlined in the Mechanical Installation section.
Complete all water piping and electrical connections.
NOTE: Field piping must be arranged and supported to avoid stress on the
equipment. It is strongly recommended that the piping contractor provide at least 3
feet (914 mm) of clearance between the pre-installation piping and the planned
location of the unit. This will allow for proper fit-up upon arrival of the unit at the instal-
lation site. All necessary piping adjustments can be made at that time. Refer to the
current engineering bulletin for further details on installation.
Units
Field-supplied,
Field-installed
Safety chains
Clevis connectors - Lifting beam
Isolation pads
Circuit breakers or fusible
disconnects (optional)
Terminal lugs
Ground connection(s)
BAS wiring (optional)
Control voltage wiring
Chilled water pump contactor and
wiring
Condenser water pump contactor
and wiring
Optional relays and wiring
Thermometers
Water flow pressure gauges
Isolation and balancing valves
water piping
Vents and drain valves
Pressure relief valves (for water
boxes as required)
Vent line and flexible connector
CGWF-SVX01A-EN