Mode
Mode
Note: It is not recommended to set the speed reference value below 100, which may cause the
peristaltic pump not to turn.
5. Set of Soda Water Flow
Open the lamp box, before filling the bottle, there is a round hole in the lower part of the back plate.
With a screwdriver, the adjusting bolt of the outlet valve is adjusted clockwise to increase the water flow
and counterclockwise to reduce the water flow.
Valve
Screw

Alarm function

The equipment includes two alarm modes: water shortage alarm and gas shortage (low pressure) alarm.
If the LED blue light belt on the cup metal button flashes intermittently, it indicates that the equipment is
in an alarm state; at this time, the sale should be stopped immediately and the alarm type should be
detected; from the lower part of the front lamp box of the equipment, the buttons from left to right, in
turn, are: the first button flashing blue light is a water shortage alarm, at this time, the soda water button
Whisky Set