Terminals (Standard Version) - Siemens SITRANS WS300 Operating Instructions Manual

Hide thumbs Also See for SITRANS WS300:
Table of Contents

Advertisement

Intrinsically Safe Version
4.2

Terminals (standard version)

1 - +V DC
The positive power supply from the integrator connection.
2 - Clockwise Speed Out
The positive output connection of the measurement loop. This output is only used when the
sensor is rotating clockwise.
3 - Counter-Clockwise Speed Out
The positive output connection of the measurement loop. This output is only used when the
sensor is rotating counter-clockwise.
4 - Common
The common connection used as a reference point with the integrator.
GND - Ground
A ground connection. Do not use this ground for the cable shield.
Note
• Ground the cable shield at the integrator end only!
• For optimal performance the housing of the Speed Sensor must be connected to a reliable
earthed ground.
SITRANS WS300
Operating Instructions, 04/2021, A5E45050935-AC
Connecting
4.2 Terminals (standard version)
21