4.2

Terminals (standard version)

1 - +V DC
The positive power supply from the integrator connection.
2 - Clockwise Speed Out
The positive output connection of the measurement loop. This output is only used when the
sensor is rotating clockwise.
3 - Counter-Clockwise Speed Out
The positive output connection of the measurement loop. This output is only used when the
sensor is rotating counter-clockwise.
4 - Common
The common connection used as a reference point with the integrator.
GND - Ground
A ground connection. Do not use this ground for the cable shield.
Note
• Ground the cable shield at the integrator end only!
• For optimal performance the housing of the Speed Sensor must be connected to a
reliable earthed ground.
4.2.1

Terminal connections to Siemens Milltronics integrators

WS300
(standard)
Milltronics
BW100
Milltronics
BW500
SITRANS WS300
Operating Instructions, 06/2018, A5E4505935-AA
1 +V
2 CW
8
7
19
16
4.2 Terminals (standard version)
3 CCW
4 Cmn
7
6
16
17
Connecting
GND
N/C
N/C