AEG CKB6540ACM User Manual page 10

Hide thumbs Also See for CKB6540ACM:
Table of Contents

Advertisement

10
www.aeg.com
3.5 Gas burners
BURNER
Auxiliary
Semi-rapid
Rapid
3.6 Gas Connection
Use a flexible pipe in compliance with the
regulation in force. Make sure they do
not come in touch with mobile parts and
are not squeezed.
WARNING!
Only a qualified and
competent person can do
the gas installation.
Before you connect te gas,
disconnect the appliance
from the electricity supply or
switch off the fuse in the
fuse box. Close the primary
valve of the gas supply.
Supply piping should not be
less than R3/8. Connection
is made to the Rc 1/2 (1/2
" B.S.P.) female threaded.
The entry pipe is located just
below the hob level on the
rear left hand side of the
appliance.
The gas supply ramp is on
the rear side of the
appliance.
WARNING!
Only liquid sealants can be
used when the inlet gas pipe
is fitted i.e.: do not use the
P.T.F.E. sealant tape.
When the installation is
complete, carry out a gas
tightness test and make sure
that the seal of each pipe
fitting does not leak.
NORMAL POWER
kW
0.95
1.9
2.8
Natural Gas
INJECTOR MARK 1/100
mm
70
96
119
Use flexible tubing, which
comply with the BS.669
current edition.
B
C
WARNING!
The gas bayonet connector
must be in the marked area.
Dimension
A
B
C
D
E
3.7 Pressure test
The Rapid injector is used as a pressure
test point.
1. Connect the pressure gauge to the
Rapid injector.
Btu/h
3242
6483
10236
A
D
C
mm
250
680
50
250
580
E

Advertisement

Table of Contents
loading

Table of Contents