Product Specific And Important Safety Information; Appliance Certification; California Safety Information; Btu & Efficiency Specifications - Vermont Castings Encore 2040-CAT-C Installation & Operating Manual

Hide thumbs Also See for Encore 2040-CAT-C:
Table of Contents

Advertisement

1
Product Specific and Important Safety Information
A. Appliance Certification
MODEL:
Encore
LABORATORY:
OMNI Test Laboratories, Inc
REPORT NO.
0135WS042E & 0135WS042S
Solid Fuel Room Heater / Wood
TYPE:
Burning Type
ASTM E2515, ASTM E2780, UL 1482-
STANDARD(s):
2011, ULC-S627-00, CAN/CSA B415.1
ELECTRICAL
115 VAC, 60 Hz
RATING:
Area Heated...................................900 - 2,300 Square feet
Loading .......................................................... Front and top
Chimney Connector: .........................................................
for 6" flue collar ...........................6" (152 mm) diameter
for 8" oval flue collar ....................8" (203 mm) diameter
Flue Exit Position ............................................Top or Rear
Primary Air ............ Manually set, thermostatically maintained
Secondary Air ................................... Fixed, self-regulating
Ash Handling System........................ Removable ash pan
Glass Panels .............................High-temperature ceramic
Weight ......................................................475 lbs. (215 kg.)
Mobile Home Approved
This appliance is approved for Installation in mobile/
manufactured homes in the United States and Canada
The structural integrity of the mobile home floor, ceiling and
walls must be maintained. The appliance must be properly
grounded to the frame of the mobile home, and must never
be installed in a room designated for sleeping. The unit must
have provisions for an outside air source when installed in
a mobile home.
B. California Safety Information
!
This product and the fuels used to operate this product
(wood), and the products of combustion of such fuels, can
expose you to chemicals including carbon black, which
is known to the State of California to cause cancer, and
carbon monoxide, which is know to the State of California
to cause birth defects or other reproductive harm. For
more information go to: www.P65Warnings.ca.gov
Proposition 65 Warning: Fuels used in gas, woodburning
or oil fired appliances, and the products of combustion
of such fuels, contain chemicals known to the State
of California to cause cancer, birth defects and other
reproductive harm.
California Health & Safety Code Sec. 25249.6
4
Vermont Castings • Encore® Model 2040-CAT-C Installation Manual_R4 • 07/19
Model 2040-CAT-C
®
WARNING
C. BTU & Efficiency Specifications
EPA Certification Number:
Catalytic Information
EPA Certified Emissions:
*EPA Default Efficiency:
**Actual tested Efficiency:
***EPA BTU Output:
****Peak BTU/Hour Output:
Other Important Information
Vent Size:
Firebox Size:
Max. Wood Length:
Ideal Wood Length:
Fuel
*An efficiency based on EPA historical data.
**Maximum calculated efficiency using Douglas Fire
dimensional lumber and data collected during EPA
emissions test.
***A range of BTU outputs based on EPA Default Efficiency
and the burn rates from the low and high EPA tests, using
Douglas Fir dimensional lumber.
**** A peak BTU out of the unit calculated using the maximum
first hour burn rate from the High EPA Test and BTU content
of seasoned cordwood (8600) times the efficiency.
This wood heater needs periodic inspection and repair for
proper operation. It is against federal regulations to operate
this wood heater in a manner inconsistent with operating
instructions in this manual.
164-18
1.1 g/hr
78.0%
76.8%
12,800 - 37,100
41,500
6 Inch (152 mm)
8 Inch (203 mm)
2.3 cu. ft.
22" Maximum
18" (Top Load)
Seasoned Cordwood
(20% moisture)
3-90-30007512

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2040Encore 2040

Table of Contents