1 1

Product Listing and Important Safety Information

A. Appliance Certification
MODEL:
Dauntless FlexBurn
LABORATORY:
Tested and Listed by OMNI Test
Laboratories, Inc
REPORT NO.
0061WS104E, 0061WS104S
TYPE:
Solid Fuel Type Room Heaters
STANDARD(s):
ASTM E2515, ASTM E3053,
UL-1482 (R2015), ULC-S627-00, B415.1
B. BTU & Efficiency Specifications
EPA Report #:
EPA Certified Emissions:
*LHV Tested Efficiency:
**HHV Tested Efficiency:
***EPA BTU Output:
****Peak BTU/Hour Output: 45,500
Vent Size:
Firebox Size:
Outside Air Size:
Recommended Length:
Max. Wood Length:
Fuel Orientation:
Fuel
*Weighted average LHV efficiency using Douglas Fir
dimensional lumber and data collected during EPA
emissions test.
**Weighted average HHV efficiency using Douglas
Fir dimensional lumber and data collected during EPA
emissions test.
***Efficiencies are based on test results calculated using
B415; these calculated efficiencies are then used to
calculate output BTU's.
****A peak BTU out of the appliance calculated using the
maximum first hour burn rate from the High EPA Test and
the BTU content of cord wood (8600) times the efficiency.
The Vermont Castings Dauntless FlexBurn
Wood Appliance meets the U.S. Environmental
Protection Agency Certified to comply with the
2020 particulate emission standards using
cord wood.
3
Wood Stove
®
240-19 (
without catalyst
246-19 (
)
catalytic
1.1 g/hr
(without catalyst)
1.2 g/hr
(catalytic)
81.6%
(without catalyst)
82.6%
(catalytic)
76.9%
(without catalyst)
77.9%
(catalytic)
12,250 - 49,430
(without catalyst)
14,520 - 41,940
(catalytic)
6 Inch (152 mm)
1.8 cu. ft.
3 Inch
16 Inch
18 Inch
East, West
Seasoned Cordwood
(20% moisture or less)
®
Vermont Castings • Dauntless FlexBurn Installation Manual_R8 • 2020 - ___ • 11/21
This wood appliance needs periodic inspection and repair for
proper operation. It is against federal regulations to operate
this wood appliance in a manner inconsistent with operating
instructions in this manual.
C. Mobile Home Approved (USA ONLY)
• This appliance is approved for mobile home installations
in the USA when not installed in a sleeping room and
when an outside combustion air inlet is installed.
• The structural integrity of the mobile home floor, ceiling,
and walls must be maintained.
• The unit must be bolted to the floor. This can be done
)
using an appropriate fastener for the application.
• The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
chimney must be listed to UL103 HT or a listed UL-1777
full length six" (152mm) diameter liner must be used.
• Mobile Home Brackets must be installed in a mobile
home installation, supplied with stove.
D. Glass Specifications
This appliance is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please contact
your dealer for replacement glass.
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:
• Installation and use of any damaged appliance.
• Modification of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not
approved by Hearth & Home Technologies.
• Operating appliance without fully assembling all
components.
• Operating appliance without legs attached (if supplied
with it).
• Do NOT Over fire - If appliance or chimney connector
glows, you are over firing.
Any such action that may cause a fire hazard.
!
WARNING
3-90-586000i

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents