8.5

Process

Temperature and pressure
Note
Pressure
Universal stamped flanges are to be used for 0.5 bar max pressure only.
Version
40 m
100 m
Maximum and minimum temperatures are dependent on the process connection, antenna
1)
and O-ring materials. Use of the Easy Aimer limits maximum temperature.
For more detail, refer to the complete operating instructions.
SITRANS LR560
Compact Operating Instructions, 02/2022, A5E39693895-AC
1)
Stainless steel flange
–40 to +100 °C
(–40 to +212 °F)
–40 to +200 °C
(–40 to +392 °F)
Aimer flange
0.5 bar max.
–40 to +100 °C
(–40 to +212 °F)
–40 to +200 °C
(–40 to +392 °F)
Technical data
8.5 Process
Aimer flange
3.0 bar max
–40 to +100 °C
(–40 to +212 °F)
–40 to +120 °C
(–40 to +248 °F)