SEF_MV (Function ID: 442081)
Setting items
OUTPUT
SEF1-2fBlk
SEF1-VTFBlk
SEF1-UseFor
SEF1-ARCBlk
EF-
Standb
SEF1S2-EN
y
SEF1S2-
UseFor
TSEF1S2
SEF2
SEF2-EN
SEF2 Directio
SEF2-Dir
n
Pol.
SEF2-Angle
SEF2-Vpol
RP
RP2-EN
RP2
SEF2 characteristic
SEF2-Timer
DT
SEF2
SEF2-DPR
TSEF2
IEC
SEF2
SEF2-DPR
SEF2-TMS-
IEC
TSEF2R
UK
SEF2
SEF2-DPR
SEF2-TMS-UK
TSEF2R
IEEE
SEF2
SEF2-DPR
SEF2-TMS-
IEEE
Rtimer
SEF2-Rtimer
TSEF2R
SEF2-RTMS-
IEEE
US
SEF2
SEF2-DPR
SEF2-TMS-US
Rtimer
SEF2-Rtimer
TSEF2R
SEF2-RTMS-
US
ORG
SEF2
SEF2-DPR
SEF2-TMS-
ORG
Range
Unit
Non / Block
- SEF1 operation block by 2f-detection
Non / Block
- SEF1 operation block by VTF
Trip / Alarm
- SEF1 used for trip or alarm
Non / Block
- Autoreclose block by SEF1
Off / On
- SEF1S2 protection enable
Trip / Alarm
- SEF1 stage2 used for trip or alarm
SEF1 stage2 operating delay time (in DT
0.00 - 300.00
s
mode)
Off / On
- SEF2 protection enable
NonDir / Forward /
- SEF2 selection of protection direction
Reverse
-90 - 90
deg SEF2 polarizing angle in directional element
3.0
V SEF2 polarizing vol. in directional element
Off / On
- Enabling RP in directional protection
0.00 – 100.00
W Threshold of residual power element
DT / IEC-NI / IEC-VI /
IEC-EI / UK-LTI /
IEEE-MI / IEEE-VI /
- SEF2 delay type
IEEE-EI / US-CO2 /
US-CO8 / Original
0.001 - 1.000
A SEF2 threshold (in DT mode)
10 - 100
% SEF2 drop-out/pick-up ratio
0.00 - 300.00
s SEF2 operating delay time (in DT mode)
0.001 - 1.000
A SEF2 threshold (in IDMT mode)
10 - 100
% SEF2 drop-out/pick-up ratio
0.010 - 50.000
- SEF2 time multiplier of IEC inverse curve
0.00 - 300.00
s SEF2 definite time reset delay
0.001 - 1.000
A SEF2 threshold (in IDMT mode)
10 - 100
% SEF2 drop-out/pick-up ratio
0.010 - 50.000
- SEF2 time multiplier of UK inverse curve
0.00 - 300.00
s SEF2 definite time reset delay
0.001 - 1.000
A SEF2 threshold (in IDMT mode)
10 - 100
% SEF2 drop-out/pick-up ratio
0.010 - 50.000
- SEF2 time multiplier of IEEE inverse curve
DEF / DEP
- SEF2 reset delay type of IEEE
0.00 - 300.00
s SEF2 definite time reset delay
SEF2 dependent reset time multiplier of IEEE
0.010 - 50.000
-
inverse curve
0.001 - 1.000
A SEF2 threshold (in IDMT mode)
10 - 100
% SEF2 drop-out/pick-up ratio
0.010 - 50.000
- SEF2 time multiplier of US inverse curve
DEF / DEP
- SEF2 reset delay type of US
0.00 - 300.00
s SEF2 definite time reset delay
SEF2 dependent reset time multiplier of US
0.010 - 50.000
-
inverse curve
0.001 - 1.000
A SEF2 threshold (in IDMT mode)
10 - 100
% SEF2 drop-out/pick-up ratio
0.010 - 50.000
- SEF2 time multiplier of Original inverse curve
- 85 -
Contents
6F2T0200 (0.15)
Default
Note
Non
Non
Trip
Block
Off
Trip
1.00
Off
Non
-45
3.0
Off
0.00
DT
0.010
100
1.00
0.010
100
1.000
0.00
0.010
100
1.000
0.00
0.010
100
1.000
DEF
0.00
1.000
0.010
100
1.000
DEF
0.00
1.000
0.010
100
1.000
GRE200 (1,2)