Multi Media Filter Tank Loading:
1. Remove yellow caplug from top of tank. DO NOT CUT white
riser tube. Tube was prefitted at the factory.
2. The distributor is permantly attached to the vortech----centering
is not necessary.
3. Cover the top opening of the distributor pipe before filling the
tank with media.
Model #
MBA-MM-1040
MBA-MM-10
MBA-MM-13
MBA-MM-1665
4. Pour all filter media provided with the unit into the top of the tank.
See page one for your specific model number of unit to
determine the amount of media to load into the mineral tank.
5. Remove the material used to cover the top opening of the
distributor pipe.
Logix Control Valve:
Gravel
1 Sand
n/a
12 lbs.
n/a
20 lbs.
n/a
25 lbs.
n/a
50 lbs.
0 Sand
45 Sand 0 Sand
8 lbs.
25 lbs.
12 lbs.
37 lbs.
16 lbs.
50 lbs.
50 lbs.
100 lbs.
Philterkol
0 Sand
45 Sand
0 Sand
1 Sand
3
Philterkol
17 lbs.
13 lbs.
25 lbs.
19 lbs.
35 lbs.
25 lbs.
80 lbs.
50 lbs.