Electrical Requirements:
Always follow all local electrical codes when installing our water
treatment equipment.
1. Provide an 115v/60Hz properly grounded dedicated electrical
Outlet. (It's very important that the polarity be correct)
Avoid using outlets that are switch controlled.
2. Maximum amperage required is 5 amps.
3. Make sure the electrical service provides power 24 hours per day.
We recommend installing a surge protector to protect unit from
power surges, which are not covered by warranty.
Logix Control Valve Electrical Connection:
Note: Do not touch the wiring harness between the Logix
timer and the motor, it's positioning is critical and therefore
already installed at the factory.
1. Remove plastic control valve cover by spreading sides while
lifting.
2. Plug transformer into back of timer following existing wires.
3. Plug transformer into a properly grounded 120V/60 HZ electrical
outlet.
4. The screen will now display "263" then the "Time of Day".