Regeneration Frequency Setting (the factory default is 7)
1) Press the SET button. The screen will show the Regeneration
frequency in blinking numbers.
2) To change the number, use the UP or DOWN arrows.
3) Press the SET button.
If you wish to regenerate on certain days ot the week, do
the following:
NOTE: The days of Regeneration will be highlighted on the
Final Check:
1. Inspect the treated water to assure that the media fines (color)
have been flushed from the unit. Make sure the drain line
connection meets all plumbing codes and that the drain line size
can handle the backwash flow rate of the multi media filter.
2. Make sure the Inlet and Outlet on bypass valve are open.
3. Make sure the control valve timer is plugged into an electrical
outlet with power 24 hours per day.
4. Check all piping for leaks.
Model #
Conditioned
Water Flow
MBA-MM-1040
MBA-MM-10
MBA-MM-13
MBA-MM-1665
a. First, do steps above, but set at zero.
b. Press SET button until you reach the day you wish
to regenerate.
c. Press the UP or Down arrows to set the day.
d. Press the SET button to lock the day in.
e. Repeat process to select the next day of
regeneration.
screen.
Specification Reference Table
Backwash
Required
Rate
5.0 gpm
6.0 gpm
5.0 gpm
6.0 gpm
8.0 gpm
10.0 gpm
12.0 gpm
15.0 gpm
Backwash
Slow Rinse
Timing
Timing
15
0 Minutes
Minutes
15
0 Minutes
Minutes
15
0 Minutes
Minutes
15
0 Minutes
Minutes
11
Fast Rinse
Timing
10 Minutes
10 Minutes
10 Minutes
10 Minutes

Advertisement