6. IPFC Use and Programming

IPFC software is extremely simple to use, but allows a wide variety of parameters to be set for ideal system calibration.
Setting Parameters are organized in 2 levels:
1: Installer level (MENU' CONTROL PARAMETERS, MENU' IN/OUT PARAMETERS, MENU' CONNECTIVITY PARAM.)
A password is required for this level; these parameters are adjustable by trained professionals
Default password:
From the menu a different password can be set up.
2. Advanced level (MENU' MOTOR PARAMETERS)
A second and different password is required; improper setting of these advanced parameters could compromise the
integrity and the life of IPFC and pump;
Default password
It is possible to set up a different password.
Installer and Advanced levels can be entered only with the correct password; otherwise, it is impossible to set up
and/or modify any parameters (they can be only displayed).

6.1 IPFC display

STOP motor
Menu exit
Alarms reset
START motor
Screen is a back-lit LCD displaying 2 rows of 16 digits each. Alarms are indicated by an audible signal.

6.2 Initial configuration

When IPFC is switched on for the first time, the initial setting menu is displayed for the initial setting of parameters to
configure pump characteristics, pressure sensor range, and system characteristics.
If the initial setting procedure is not completed properly, it is impossible to run the pump. Initial setting procedure can be
repeated if necessary.
The initial setting procedure can be repeated (by using the 2
different system.
A brief description of parameters and their allowable ranges are listed below:
001
002
rd
level password) to reconfigure IPFC or if IPFC is installed in a