Functional Description Of The Terminal; Functional Description; Features Of The Terminal; Fig. 1-1: The R-Ib Il Cnt Terminal With Its Appropriate Connectors - Bosch Rextroth Indramat RECO R-IB IL CNT Applications Manual

Inline counter terminal
Table of Contents

Advertisement

Counter Terminal
1

Functional Description of the Terminal

1.1

Functional Description

Features of the Terminal

DOK-CONTRL-R-IL*CNT***-AW02-EN-P
The R-IB IL CNT terminal is a counter terminal designed for use within an
inline station. The counter terminal is also simply called a counter.
The counter detects and processes fast pulse sequences of sensors. It
has a counter input (source), a control input (gate) and a freely
configurable switch output that is set independently by the module. Fast
reaction times that are independent of the bus and the control system can
thereby be achieved.
The terminal can be operated in four different modes. These modes are:
frequency measurement, event count, time measurement and pulse
generator.
Sensors with 24 V DC power supply and 5 V DC power supply can be
connected at the terminal.
The connection output delivers a maximal current of 500 mA.

Fig. 1-1: The R-IB IL CNT terminal with its appropriate connectors

• Event counting:
The counting conditions and the output switching condition can be
freely selected.
• Frequency measurement:
Time and condition visualisation controlled frequency measurements
with gate times (time of the measurement) between 10 ms and 10 s
can be made.
• Time measurement:
Comparative
conditions
measurement. The evaluation result can be outputted by the process
data or at the digital output. This allows a targeted reaction to be made
if limit values are exceeded or fallen short of.
Functional Description of the Terminal