I N S TA L L AT I O N G U I D E L I N E S
FLAMMABLE MATERIAL WARNING
Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyro-
technics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installa-
tions.
USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES, AS THE POWER
CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER
OUTPUT ON THIS FIXTURE. CHECK SILK SCREEN FOR MAX AMPS.
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and
construction codes and regulations.
Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or
placing the fixture(s) on any surface, a professional equipment installer MUST be consulted to
determine if the metal truss/structure or surface is properly certified to safely hold the com-
bined weight of the fixture(s), clamps, cables, and accessories.
Ambient operating temperature range for this fixture is 14°F to 113°F (-10°C to 45°C). Do
not operate the fixture when the ambient temperature falls outside of this range.
Fixture(s) should be installed away from walking paths, seating areas, or areas were unauthor-
ized personnel might reach the fixture by hand.
NEVER stand directly below the fixture(s) when rigging, removing, or servicing.
Overhead fixture installation must always be secured with a secondary safety attachment,
such as an appropriately rated safety cable that meets all local, national, and country codes
and regulations.
Allow approximately 15 minutes for the fixture to cool down before servicing.