TOOL INSTALLATION INSTRUCTIONS AND USE
Lubrication
To insure maximum performance, install an air set
(oiler, regulator, air filter) as close as possible t o the
tool. Adjust the oiler so that one drop of
oil
will be
provided for every 30 nails.
When an air
set is
not used, oil the tool with pneuma-
t i c tool oil by placing 2 (two) or
3
(three) drops into
the air fitting. This should be done before and after
use. For proper lubrication, the tool must be fired
a
couple of times after pneumatic tool oil is introduced.
7
Pneumatic tool oil
Loading nailer
CAUTION :
Always disconnect the air hose before loading nails into the nailer.
Select nails suitable for your work.
Depress the latch lever and open the magazine cap.
Lift and turn the coil support plate so that the arrow
with nail size indicated on the coil support plate will
point t o the corresponding graduation increment
marked on the magazine. If the tool is operated with-
out the arrow pointing t o the proper graduation pro-
perly, poor nail feed or malfunction of the tool may
result.