Download Print this page

Temperature Measurement; Inclination Angle - Fluke 393 FC Quick Start Manual

Solar tools kit with clamp meter, irradiance meter and solar test leads
Hide thumbs Also See for 393 FC:

Advertisement

International
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies
buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and
radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)
USA (FCC)
Safety
General
Measurement
Wireless Radio
Radio frequency certification
Wireless Radio Frequency Range
Output Power
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address:
www.fluke.com/en-us/declaration-of-conformity
Specifications: Fluke Solar Irradiance Meter
Irradiance
Measuring Range
Resolution
Measuring Accuracy

Temperature Measurement

Measuring range (°C) -22 °F to 212 °F (-30 °C to 100 °C)
Resolution
0.2 °F (0.1 °C) / 1 °F @>100 °F
±2 °F (±1 °C) @ 14 °F to 167 °F (-10 °C to 75 °C),
Measuring Accuracy
±4 °F (±2 °C) @ -22 °F to 14 °F (-30 °C to -10 °C) and 167 °F to 212 °F (75 °C to 100 °C)
Note: Temperature measurement response time: ~30 sec.

Inclination Angle

Measuring Range
-90° to +90°
Resolution
0.1°
Measuring Accuracy ± 1.5°@ -50° to +50°, ±2.5° @ -85° to -50° and +50° to +85°, ±3.5° @ -90° to -85° and +85° to +90°
Compass
Measuring Range
5 Fluke Corporation
Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads
IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11:
Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled
radio frequency energy that is necessary for the internal function of the equipment
itself.
Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is intended
for use in business environments and not to be used in homes.
47 CFR 15 subpart B. This product is considered an exempt device per clause
15.103.
IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
FCC ID: T68-FBLE, IC: 6627A-FBLE
2400 MHz to 2483.5 MHz
<100 mW
0 to 1400 W/m²
1 W/m²
± (5 % + 5 Digit)
0° to 360°
https://www.fluke.com/en-us/product/electrical-testing/clamp-meters/solar-tools-393-irrsol