F3 Parameters Setting By Energization After Correct Connection - Electrolux EUC40G1 Instruction Manual

Table of Contents

Advertisement

F3 Parameters Setting by Energization after Correct Connection

The parameters may be set after energization, in OFF state, and when the unit's decimal point of the
PV window is flickering:
Press the "Set" key to enter into the setting state. The main washing temperature display window shows "PA-", indicating entry of
password. The rinsing temperature display window shows "0".
Press the numerical digit UP key, the PV window shows numerical digit. Enter the password and press the "Set" key. If the password
is incorrect, enter into the parameter setting. Otherwise, return. (The defaulted user password is 65)
The main washing temperature display window shows "P1-", indicating the rinsing temperature setting. The rinsing temperature
display window shows the original setpoint. Press the numerical digit UP or DOWN key to modify the rinsing temperature setpoint.
(Setting range: 70-90°C, STD model defaulted value: 82°C, TL model defaulted value: 85°C )
Press the "Set" key, the main washing temperature display window shows "P2-", indicating the main washing temperature setting.
The PV window shows the original setpoint. Press the numerical digit UP or DOWN key to modify the main washing temperature
setpoint. (STD model setting range: 40-70°C, defaulted value: 60°C ; TL model setting range: 40-80°C, defaulted value: 75°C)
Press the "Set" key, the main washing temperature display window shows "P3-", indicating the filling water temperature setting.
The rinsing temperature display window shows the original setpoint. Press the numerical digit UP or DOWN key to modify the filling
water temperature setpoint.
(STD model setting range: 10-70°C, defaulted value: 60°C; TL model setting range: 10-80°C, defaulted value: 75°C)
Press the "Set" key, the XV window shows "P4-", indicating the rinsing restricted temperature setting. The rinsing temperature
display window shows the original setpoint. Press the numerical digit UP or DOWN key to modify the rinsing restricted temperature
setpoint. (STD model setting range: 10-82°C, defaulted value: 82°C; TL model setting range: 10-90°C, defaulted value: 85°C)
Press the "Set" key, the main washing temperature display window shows "P5-", indicating the rinsing time setting. The rinsing
temperature display window shows the original setpoint. Press the numerical digit UP or DOWN key to modify the rinsing time
setpoint. (Setting range: 8-15 s, defaulted value: 10 s)
Press the "Set" key, the main washing temperature display window shows "P6-", indicating the water supplying delay time setting.
The rinsing temperature display window shows the original setpoint. Press the numerical digit UP or DOWN key to modify the water
supplying delay time setpoint. (Setting range: 5-40 s, defaulted value: 20 s)
Press the "Set" key, the main washing temperature display window shows "P7-", indicating the mode setting. The rinsing
temperature display window shows the original setpoint. Press the numerical digit UP or DOWN key to modify the mode setpoint.
(Setting range: 0-1, defaulted value: 0)
21