Panasonic DPH-L100 Instruction Manual page 2

Separate type digital sensor controller

Advertisement

SETTING WHEN TURNING ON THE POWER
7
● After turning ON the power, set pressure range of pressure sensor head con-
nected to this product. The set pressure range is memorized and the range is
displayed every time after tuning on the power. Then, move to RUN mode.
● In case replacing sensor head or resetting it, set the pressure range again.
Turning ON the power
Pressure range
setting
-0.1 to 1MPa
0 to 1MPa
Check the set
pressure range
Resetting the
Confirm the set
pressure range
pressure range
The set pressure range is displayed.
RUN MODE
8
Setting the threshold value
● Refer to <Comparative output 1 / 2 output mode setting> in "
SETTING MODE" for setting conditions.
● The Sub display conducts the threshold value. Main display does not changed.
Display is changed by pressing down.
EASY mode
(Comparative output 2 is OFF)
Comparative
output 1
EASY mode
Comparative
output 2
Comparative
output 1
Hysteresis mode / Window
comparator mode · Lo side
Comparative
output 2
Comparative
Hysteresis mode / Window
output 1
comparator mode · Hi side
Comparative
output 2
Notes: 1) If the set pressure range is exceeded, "
limit) will appear on the sub display. "
Lo side threshold value when setting the "hysteresis mode / window comparator mode" threshold value.
2) Auto-reference value and remote zero-adjustment value are displayed.
For details, refer to "
AUTO-REFERENCE FUNCTION" and "
FUNCTION."
3) In the dash line box is not displayed when not setting "
setting method, refer to<Function setting> in "
Zero-adjustment function
● The zero-adjustment function forcibly sets the pressure value to "zero" when
the pressure port is opened.
Hold down
Note: Even if the zero-adjustment is conducted, the analogue voltage / current output is not influenced.
Key lock function
● The key lock function prevents key operations so that the conditions set in
each setting mode are not inadvertently changed.
<Key lock set>
Hold down
<Key lock released>
Hold down
Peak / bottom hold function
● The peak / bottom hold functions display the peak value and bottom value of
the fluctuating pressure.
PEAK / BOTTOM HOLD FUNCTION. "
For detail, refer to "
● The peak value is displayed on the main display and the bottom value is dis-
played on the sub display.
● the higher vacuum side indicates the peak value, while the lower vacuum side
indicates the bottom value.
<Peak / bottom hold set>
Hold down
<Peak / bottom hold released>
Hold down
0 to 3.5MPa
0 to 10MPa
0 to 50MPa
RUN mode
Automatic
Press down: increase threshold value to high pressure side.
Press down: decrease threshold value to low pressure side.
Blinks alternately
(Note 2)
(Note 3)
" (exceeds the upper limit) or "
" (exceeds the lower
" will also appear if the Hi side threshold value exceeds the
REMOTE ZERO-ADJUSTMENT
" or "
" in external input switch. For the
MENU SETTING MODE."
Automatic
Automatic
Automatic
Blinks alternately
MENU SETTING MODE
9
● The mode will change to RUN mode when the mode selection key is held
down during this setting process. In doing so, changed items before holding
down the mode selection key have been set.
RUN mode
Press for 2 sec.
<Comparative output 1 output mode setting>
EASY mode
<Comparative output 2 output mode setting>
OFF mode
<N.O. / N.C. selection> (When the comparative output 2 output mode setting is set to OFF)
N.O.
MENU
<N.O. / N.C. selection> (When the comparative output 2 output mode setting is set to other than OFF)
Output 1: N.O.
Output 2: N.O.
<Analogue voltage / current output selection>
Analogue
voltage
output mode
<Function setting>
OFF
<Response time setting>
5ms
<Display color selection of the main display>
Red when ON
Green when OFF
<Unit selection> (Note 1)
MPa
<RUN mode>
Note: 1) In case connecting pressure range 1MPa type of pressure sensor head to Japanese model controller,
only "MPa" or "kPa" can be set. Also, in case connecting 3.5MPa or more type, setting item for unit
change is not displayed.
2) in case of connecting pressure range 3.5MPa type of sensor head to out side of japan type controller.
"
" is not displayed.
Setting Item
Comparative
output 1 output
mode setting
Comparative
output 2 output
mode setting
N.O. / N.C.
selection
Analogue voltage
/ current output
selection
Function setting
Response time
setting
Display color
selection of the
main display
Unit selection
Hysteresis
Window com-
mode
parator mode
Window
Hysteresis
comparator
EASY mode
mode
mode
N.C.
Output 1: N.C.
Output 1: N.O.
Output 1: N.C.
Output 2: N.C.
Output 2: N.C.
Output 2: N.O.
Analogue
current out-
put mode
Current
Remote zero-
Auto-reference
adjustment
value hold
function mode
function mode
function
10ms
5,000ms
Green when ON
Red when OFF
Always red
Always green
2
kPa (Note 2)
kgf/cm
bar
Factory setting
Sets comparative output 1 output mode.
Sets comparative output 2 output mode.
Sets when Nomal Open (N.O.) or Normal Close (N.C.).
Initial state of excepting OFF of the comparative output 2 setting is "
Selects Analogue voltage output or analogue current output.
Sets Auto-reference function or remote zero-adjustment function and current
value hold function or peak / bottom 2 function.
Sets response time.
The response time can be select from 5ms, 10ms, 25ms, 50ms, 100ms,
250ms, 500ms, 1,000ms or 5,000ms.
Selects display coler of main display.
Selects pressure unit.
Auto-peak /
bottom hold
2 function
psi
Description
."