Panasonic DPH-L100 Instruction Manual page 3

Separate type digital sensor controller

Advertisement

PRO MODE
10
● The mode will change to RUN mode when the mode selection key is held
down during this setting process. However, changed items before holding
down the mode selection key have been set.
RUN mode
When "No. display" or "Custom display" is set in "Sub display selection."
Hold down
for 4 seconds
<Sub display selection>
When "
" is set
<PRO mode>
When "
" is set
Set pressure
range is displayed
on sub display.
<Sub display selection>
Standard
Display OFF
Unit display
<Display speed selection>
250ms
500ms
1,000ms
<Hysteresis fixed value selection> (1 level: Approx. 1 digit) (When Pa unit is selected.)
<Displayed color relation selection>
Relating with
Relating with
comparative
comparative
output 1
output 2
<External input relation selection>
Corresponding
Corresponding
Corresponding
to comparative
to comparative
to comparative
output 2
output 1 / 2
output 1
<Eco mode setting>
OFF
Standard
Max.
<Setting check code>
Automatic
<Setting copy mode>
Copy sending
Copy sending
Copy sending
ON
ON-L
OFF
<Reset setting>
RUN mode
Setting item
Factory setting
Changes the indication of the sub display in RUN mode.
"
" : Displays nothing.
Sub display
"
" : Current pressure unit is displayed.
selection
"
" : Desired No. can be shown.
"
" : Desired numbers, alphabets (some of them cannot be displayed)
and signs can be shown.
Display speed
Changes the speed of the displayed pressure value on the main display.
selection
Hysteresis fixed
Sets hysteresis of the EASY mode and the window comparator mode.
value selection
(8 steps)
Displayed color
The setting contents set at the displayed color setting in Menu setting mode
relation selection
can be related with either comparative output 1 or comparative output 2.
External input
The setting contents set at auto reference function and remote zero-adjustment
relation selection
function can be shifted to correspond to either comparative output 1, 2 or 1 / 2.
Current consumption can be lowered.
"
" : Normal operation (ECO mode is OFF.)
"
" : If any key operation is not carried out for approx. 5 sec. in RUN
Eco mode
mode, the display becomes dark.
setting
"
" : If any key operation is not carried out for approx. 5 sec. in RUN
mode, the display is turned OFF.
Press any key to temporarily show the normal indication.
Setting check
Current setting contents can be checked. For codes. refer to "Code table."
code
The setting of the master side sensor can be copied to the slave side sensors.
For details, refer to "
Setting copy
"
" : The setting contents are copied.
mode
"
" : The setting contents are copied, and the slave side sensor goes
into key-lock state.
Returns to default settings (factory settings).
Reset setting
By pressing dowun mode key when "
(factory settings).
Change the displayed
details with
RUN mode
No. display
Custom display
Max.
Min.
Copy ready
state
Description
SETTING COPY FUNCTION."
" mode, becomes default settings
Code table
● Main display (first digit form left)
1st digit
2nd digit
Comparative
Comparative
N.O. / N.C.
output 1 output
output 2 output
selection
mode
mode
N.O.
OFF
EASY
N.C.
EASY
N.O.
Hysteresis
N.C.
Hysteresis
N.O.
Window
comparator
N.C.
Window
comparator
-
-
-
-
-
AREF: Auto-reference function, ZERO: Remote zero-adjust function,
HOLD: Current value hold function P.b.-2: peak / bottom hold 2 function
● Sub-display (5th digit from left)
5th digit
6th digit
Displayed color of
Displayed color
Response time
the main display
relation
Comparative
output 1
Red when ON
Comparative
output 2
Comparative
Green when
output 1
ON
Comparative
output 2
Comparative
output 1
Always red
Comparative
output 2
Comparative
output 1
Always green
Comparative
100ms
output 2
-
-
250ms
-
-
500ms
-
-
1,000ms
-
-
5,000ms
11
SETTING COPY FUNCTION
● This can copy the settings of the master side sensor to the slave side sensor.
● Be sure to use the setting copy function between the identical models. This
function cannot be used between different models.
● Only one sensor can be connected on slave side with a master side sensor
for the setting copy function.
● Do not use the setting copy function other than the following wiring, as pulsed output gener-
ates when turning the power ON after setting the master side sensor to the copy ready state.
Setting procedure
1. Set the setting copy function of the master side sensor to "Copy sending ON
" or "Copy sending ON-L" with the pressure sensor head connected, and then
press the mode selection key so that the sensor is in copy ready state. For de-
tails, refer to <Setting copy mode> in "
2. Turn OFF the master side sensor.
3. Remove the pressure sensor head and connect the master side sensor with
the slave side sensor as shown below.
Color code of cable
with connector
Master side sensor
(Brown) +V
(Blue) 0V
(Black) Comparative output 1
(Pink) External input
4. Turn ON the master side sensor and the slave side sensor at the same time. (Note)
5. Set contents (16-bit coded) are shown in orange on the main display of the
master side sensor and the copying starts.
6. The same code explained above is shown in green on the main display of the slave
side sensor, and "
" is shown on the sub display (When copying is complete.)
7. Turn OFF the power of the master side sensor and the slave side sensor and
disconnect the wire.
* If copying the setting to another sensor repeatedly, follow steps 3 to 7.
Note: Take care that if the power is not turned on at the same time, the setting contents may not be copied.
To cancel the setting copy mode of master side sensor
1. While the slave side sensor is disconnected, turn on the power of the master side sensor.
2. Press the mode selection key for approx. 2 seconds.
12
AUTO-REFERENCE FUNCTION
● The auto-reference function
corrects the set value using
the detected pressure value
during auto-reference input
as the reference pressure.
● Using the detected pressure
value at auto-reference input
P(a) as a reference, the set
value 1' is automatically cor-
rected to "set value 1 + P(a)."
Settable range and set pressure range after correction
● The setting pressure range is wider than the rating pressure range so that the
auto-reference function can be handled.
If the corrected set value exceeds the set pressure range when auto-reference
input is carried out, the set value will be automatically corrected to within the set
pressure range. Thus, take care not to exceed the set pressure range.
3rd digit
N.O. / N.C.
Analogue
Threshold
selection
output
display
Threshold
-
value 1
Threshold
Analogue
N.O.
value 2
voltage
Threshold
N.C.
output
value 3
Threshold
N.O.
value 4
Threshold
N.C.
value 1
Threshold
Analogue
N.O.
value 2
current
Threshold
N.C.
output
value 3
Threshold
-
value 4
7th digit
8th digit
Unit selection
Display speed
(Note)
-
MPa
-
kPa
250ms
2
-
kgf/cm
5ms
bar
10ms
psi
500ms
25ms
-
50ms
-
1,000ms
-
-
-
-
-
-
-
-
PRO MODE."
Power
supply
Slave side sensor
(Brown) +V
(Blue) 0V
(Black) Comparative output 1
(Pink) External input
Before auto-
reference
After auto-
reference
Atmospheric pressure
P (a)
Set value 1 Set value 1'
Pressure
Detected pressure value
Set value 1' after auto-reference is:
at auto-reference input
1' = 1 + P (a)
4th digit
External
input
OFF
AREF
ZERO
HOLD
P.b.-2
-
-
-
Eco mode
OFF
std
Full
OFF
std
Full
OFF
std
Full
-
-
-
ON
OFF
ON
OFF