When a load of apples is going to be picked up, the operator simply selects "APPLES" from the IntelliSet menu; for
cheese, "CHEESE" is selected; for ice cream, "ICE CREAM" is selected. With each selection, the control system
automatically re-programs the settings to provide the best temperature control, fuel economy, and performance for
that particular product.
The above settings are examples of possible settings. Factory IntelliSets are available from your authorized
Carrier Transicold Truck/Trailer dealer.
• An IntelliSet may be pre-programmed as "IntelliSleep" which allows Sleep Mode to be entered by simply
changing to that IntelliSet.
Range Protect may be applied to as many IntelliSets as desired. Range Protect is designed to prevent freez-
ing or overheating of non-sensitive cargo by locking the unit in Start-Stop Operation when the compartment
temperature is in the preset range (default range is 35 to 70°F, 1.6 to 21.1°C). Range Protect offers
increased fuel savings over normal Start-Stop Operation.
START/STOP
START/STOP
CONTINUOUS
Viewing Menu Soft Key
DEFROST
Press Menu Key to Scroll
MENU
INTELLISET
2
1. With the system powered up (START/RUN-OFF switch in the START/RUN position) or in PC Mode and the
default screen displayed, press the "=" key. If the screen shown just above step 3 below is displayed, pro-
ceed to step 3. Otherwise, proceed to step 2.
2. Press the MENU key until INTELLISET is displayed. Then, press the INTELLISET soft key to display the
IntelliSet screen.
3. The IntelliSet screen will display with a 10 second timeout and five of the available IntelliSets listed. There
may be more than five IntelliSets available. This information is provided, in parenthesis, on the first line. For
example, in the preceding illustration there are seven IntelliSets available and the second IntelliSet is high-
lighted. Press the ▲ or ▼ key to scroll through the list of available IntelliSets. The IntelliSet that is currently
selected will have the word "ACTIVE" or "MODIFIED" to the right.
4. To change to another IntelliSet, press the ▲ or ▼ key to scroll through the list and highlight the IntelliSet
desired. Press the "=" Key. The highlighted IntelliSet will become active and an "INTELLISET CHANGED"
message will display.
5. Press the EXIT soft key to return to the default display.
If setpoint change is allowed, refer to
If it is desirable to have this machine go directly to the IntelliSet screen on a press of the "=" key, set the
"ENABLE INTELLISET AT = KEY" Configuration to "YES". Refer to
62-11637
NOTES
ALARM
DIESEL
COOL
Selections
PRETRIP HOUR
UNIT
METERS
DATA
NOTES
Section 3.6
3
1 & 4
IntelliSet Off
Banana
Flowers
3
Lettuce
Cheese
for setpoint change instruction.
Section
3–4
IntelliSets