Carrier X4 7300 Operation & Service Manual page 123

Trailer and rail refrigeration units
Hide thumbs Also See for X4 7300:
Table of Contents

Advertisement

Message
TECHNICIAN
RESET
(AL00021)
TIME SELECTION NOT CHANGED
TRIP START ENTERED
UNIT BATTERY TOO LOW
UNIT SHUTDOWN − DOOR OPEN
UNIT SHUTDOWN − SEE ALARM
LIST
UNIT SHUTDOWN − RMS1
USE UP/DOWN KEY TO SCROLL USE
= KEY TO SELECT ITEM TO CHANGE
VIEWING MENU SOFTKEY SELEC-
TIONS
PRESS
MENU
SCROLL
WARNING: NO TEMP CONTROL
62-11637
Table 6–1 MessageCenter Messages
REQUIRED
AL00011 (Low Engine Oil Pressure) or AL00012 (High Coolant Tempera-
ture) has been activated three times in the last two hours and the unit has
been locked out. Refer to
A time change was started but not entered (saved) in Configuration List.
The Trip Start marker has been placed in the DataLink data recorder.
The unit battery has dropped below 7 volts for more than 10 seconds.
The unit has shutdown because the refrigerated compartment door is
open.
An active shutdown alarm has shut the unit down.
The unit has shutdown because switch is open. May be connected to a
door or a remote control switch.
Items available are being displayed or additional items are available for
selection. Use the up or down arrow key to highlight or display and high-
light the desired selection and then use the "=" key to select it.
Additional soft key selections are available and the MENU key is to be
KEY
TO
used to scroll and view them.
The temperature sensors have failed and the unit has entered Cargo Pro-
tect Mode. Refer to
Description
Section 7
for further information.
Section
4.11.1.