Carrier X4 7300 Operation & Service Manual page 116

Trailer and rail refrigeration units
Hide thumbs Also See for X4 7300:
Table of Contents

Advertisement

Configuration
• REMOTE SWITCH 1
ENABLE
ADVANCED
USER MODE:
PROTECT DATA WITH PIN YES / NO
PARAMETERS LOCKOUT YES / NO
8
HOURS
ADDITIONAL
DATA
HIGH SPEED DELAY
LIGHT BAR
62-11637
Table 5–1 Configuration Settings
Selections
ALARM ONLY
UNIT SHUTDOWN
LOW ENGINE SPEED
DATA RECORDER ONLY
OTHER SETTINGS
YES / NO
YES / NO
1 Minute
0 to 10 minutes in 0.5 minute
increments
NOT INSTALLED
2 LIGHT
5–26
Description
ALARM ONLY = When the switch is activated, a
warning alarm will be displayed in the Message-
Center.
UNIT SHUTDOWN = When the switch is activated,
a warning alarm will be displayed in the Message-
Center, and the unit will shutdown.
LOW ENGINE SPEED = When the switch is activat-
ed, the engine will be forced to low speed.
DATA RECORDER ONLY = The DataLink data re-
corder will record every time the switch is activated.
There will be no alarms or messages displayed in
the MessageCenter.
YES = Advanced User Mode is automatically en-
abled when the unit is powered on.
NO = Driver Mode is automatically enabled when the
unit is powered on and Advanced User Mode may be
enabled manually.
NOTE
master technician PIN code is described
in
Section
5.2. Using the TRUtech pro-
gram, a data protect PIN code, which can
override the master technician PIN code,
may be entered into the control system.
YES = The data protect PIN code will override the
master technician PIN code and the data protect
code must be entered to use the USB Interface port
or data recorder print functions.
NO = The data protect PIN code, if entered, will not
override the master technician PIN code when using
the USB Interface port or data recorder print functions
YES = All Functional Parameters are locked and
cannot be changed using the display mounted keys.
NO = Functional Parameters can be changed using
the display mounted keys, unless individually locked
out by TRU-Tech.
YES = When the START/RUN−OFF switch is placed
in the OFF position, the DataLink data recorder will
continue to record data for an additional 8 hours.
NO = When the START/RUN−OFF switch is placed
in the OFF position, the DataLink data recorder will
stop recording data.
Select the length of time unit remains in low speed
before transitioning to high speed.
NOT INSTALLED = a remote light bar is not installed
2 light = a two light bar is installed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

X4 7500

Table of Contents