The item specify how the system will be awakened from power saving
mode when input signal of the keyboard is detected. If set to Specific
Key, <Ctrl+Alt+BackSpace> is the only one Power On event. If set to
Password, please press <Enter> to input password and its maximum
password is 5 character. Options are: Disabled, Any Key, Specific Key
and Password.
Resume By Alarm
If Resume By Alarm is set to Enabled, the system will automatically
resume (boot up) on a specific date/hour/minute/second specified in
these fields. Available settings for each item are:
Alarm Date
Alarm Hour
Alarm Minute
Alarm Second
01~31, Every Day
00~23
00~59
00~59