Quartz and O'ring Installation:
1. Wipe the quartz sleeve with household alcohol to remove dirt, oil
and fingerprints.
2. Carefully place the quartz sleeve into the top opening of the
vessel.
3. Lubricate the o'ring with silicone (which is supplied) then place the
o'ring over the top of the quartz sleeve.
4. Hand-tighten the clear gland nut onto the nipple located on the top
of the vessel.
shatter. When operating, the clear gland nut will glow blue.
Germicidal Lamp Installation:
1. Clean the germicidal lamp with household alcohol to remove dirt,
oil and fingerprints.
2. Remove jumper wire from white-end connection of power supply
and insert UV lamp pins in place of jumper wire.
3. Gently insert the germicidal lamp into the quartz sleeve through
the center of the clear gland nut located at the top of the vessel.
Be careful not to drop the lamp inside the vessel. This could
break the quartz sleeve.
4. Slide the black fitting into the center of the clear gland nut.
Power Supply Start Up:
1. Press the reset button (hold for 5-seconds and release) which is
located in the lower center of the circuit board left of the battery.
2. Re-install cover.
3. Plug the power supply into the surge protector (not provided) then
into dedicated electrical outlet. The germicidal lamp is now operating
and the solenoid is energized to open.
Filling the UV Unit with Water:
1. Open the inlet ball valve about 25% to fill the UV vessel slowly.
2. Open the inlet and outlet ball valve to their full open position.
3. Open cold water faucet in kitchen and run until all air is purged.
Shut off faucet.
4. Inspect for leaks and repair if any are found.