Always follow all local electrical codes when installing our
water
Treatment equipment.
1. Provide a 115v/60Hz properly grounded a dedicated electrical
outlet. (It's very important that the polarity be correct)
Avoid using outlets that are switch controlled.
2. Maximum amperage required is 5 amps.
3. Make sure the electrical service provides power 24 hours per day.
We recommend installing a surge protector to protect unit from
power surges, which are not covered by warranty.
!!! DO NOT UNDER ANY CIRCUMSTANCE WIRE THE UV
UNIT TO THE WELL PUMP SWITCH OR WELL PUMP
ELECTRICAL SUPPLY !!!
MWC-ES Power Supply Installation:
1. Choose a wall placement that is dry and clear of all piping and
metal objects, and within 4 feet of the UV vessel and the
electrical outlet.
2. Remove cover from power supply for mounting.
3. Secure power supply to wall with screws (not provided).
SEE THE FOLLOWING PAGE FOR PROPER
GROUNDING INSTRUCTIONS.