Quartz and O'ring Installation:
1. Wipe the quartz sleeve with household alcohol to remove dirt, oil and
fingerprints.
2. Carefully place the quartz sleeve into the top opening of the vessel.
3. Lubricate the o-ring with silicone (which is supplied) then place the o'ring
over the top of the quartz sleeve.
4. Hand-tighten the clear gland nut onto the nipple located on the top of the
vessel.
Do not over tighten or the quartz sleeve may shatter.
When operating, the clear gland nut will glow blue.

Germicidal Lamp Installation:

1. Clean the germicidal lamp with household alcohol to remove dirt, oil and
fingerprints.
2. Remove jumper wire from white-end connection of power supply and
insert UV lamp pins in place of jumper wire.
3. Gently insert the germicidal lamp into the quartz sleeve through the
center of the clear gland nut located at the top of the vessel. Be careful
not to drop the lamp inside the vessel. This could break the quartz
sleeve.
4. Slide the black fitting into the center of the clear gland nut.

Power Supply Start Up:

1. Press the reset button (hold for 5-seconds and release) which is
located in the lower center of the circuit board left of the battery.
2. Re-install cover.
3. Plug the power supply into the surge protector (not provided) then
into dedicated electrical outlet. The germicidal lamp is now operating.
Filling the UV Unit with Water:
1. Open the inlet ball valve about 25% to fill the UV vessel slowly.
2. Open the inlet and outlet ball valve to their full open position.
3. Open cold water faucet in kitchen and run until all air is purged.
Shut off faucet.
4. Inspect for leaks and repair if any are found.