[Slot Setting] - Panasonic PT-RQ25K Series Operating Instructions (Functional Manual)

Table of Contents

Advertisement

Zoom Lens with DC motor, the Fixed-focus Lens
This section describes the operating procedure when the Zoom Lens (Model No.: ET-D75LE6, ET-D75LE8,
ET-D75LE10, ET-D75LE20, ET-D75LE30, ET-D75LE40, etc.) in which the DC motor has not been replaced
with the stepping motor unit is attached, or when the Fixed-focus Lens (Model No.: ET-D3LEW50, ET-D75LE50,
ET-D75LE95, ET-D3LEF70, etc.) without the zoom function is attached. Refer to "Zoom Lens with the stepping
motor" (x page 177) when a projection lens with stepping motor is attached.
1)
Press as to select [LENS].
2)
Press the <ENTER> button.
f The [LENS] screen is displayed.
3)
Press as to select [LENS CALIBRATION].
4)
Press the <ENTER> button.
f The confirmation screen is displayed.
5)
Press qw to select [OK], and press the <ENTER> button.
f The lens calibration is started. The calibrations for the lens shift, focus, and zoom are performed when the
Zoom Lens is attached. The calibrations for the lens shift and focus are performed when the Fixed-focus
Lens is attached.
f After completing the calibration in the adjustment range, the projection lens will move to the home position.
f To cancel, select [CANCEL].
Note
f Pressing the <FOCUS> button on the remote control for at least three seconds will also display the confirmation screen for lens calibration
execution.
f [LENS CALIBRATION] cannot be executed when the [PROJECTOR SETUP] menu → [LENS] → [LENS TYPE] is set to [NOT SELECTED].
f [PROGRESS] is displayed in the menu during lens calibration. The operation cannot be canceled during calibration.
f [INCOMPLETE] is displayed when the lens calibration is not performed correctly.
f The origin position of the lens mounter and the home position of the projection lens are automatically updated when the lens shift calibration
is performed. The home position is an origin position of the lens shift (vertical position and horizontal position of the lens) based on the
calibration result. It does not match with the optical image center position.
f The home position varies depending on the projection lens type. For details, refer to "Lens shift range" (x page 92).

[SLOT SETTING]

Set the power supply to the slot.
The content that can be set varies depending on the Function Board installed in the slot. This cannot be set when
the Function Board is not installed.
[SLOT STANDBY]
Set the power supply during the standby mode.
1)
Press as to select [SLOT STANDBY].
2)
Press qw to switch the item.
f The items will switch each time you press the button.
[ENABLE]
[DISABLE]
Note
f [SLOT STANDBY] is fixed to [DISABLE] when the following Function Board is installed.
g 12G-SDI Terminal Board (Model No.: TY-SB01QS)
g Wireless Presentation System Receiver Board (Model No.: TY-SB01WP)
g Function Board by other manufacturers
[SLOT POWER ON]
Start the power supply that was stopped.
1)
Press as to select [SLOT POWER ON].
178 - ENGLISH
Chapter 4 Settings — [PROJECTOR SETUP] menu
The power is supplied to the Function Board even when the projector is in standby mode.
The power supply to the Function Board is stopped when the projector goes into standby mode.

Advertisement

Table of Contents
loading

Table of Contents