STATIC FILTERING

If you select Static Filtering from the Advanced Management screen, the follow-
ing Static Filtering screen will appear, with Source MAC Address highlighted.
From the Static Filtering screen, you can select Source MAC Addresses
Destination MAC Addresses and MAC Address In-Filters for static filtering by
highlighting one of these options and pressing the Enter key.
If you select Source MAC Address and press Enter, the SRC MAC Out-Filter
screen will appear.
If you select Destination MAC Address and press Enter, the DST MAC Out-
Filter screen will appear.
If you select MAC Address In-Filters, the MAC Address In-Filters screen will
appear.
62
ProConnect II
®
Series
2224 Layer 2 Management 24-Port 10/100 Ethernet Switch
From each of these screens, you are able to:
• Hold down the Shift key and press the "+" key to add a specific MAC
address to be filtered.
• Press the "-" (hyphen) key to delete a specific MAC address from being
filtered. Since there is no precautionary message that appears before you
delete a specific MAC address, be sure you want to delete the address
before you begin.
• Press "S" to search through the list of MAC addresses in the static filtering
database. The static filtering database maximum capacity is 64.
When you finish, press the Esc key until you return to the desired screen.

SPANNING TREE FUNCTIONS

If you select Spanning Tree from the Advanced Management screen, the
Spanning Tree Protocol screen will appear.
Spanning Tree Protocol Configurations
Highlight Spanning Tree Configurations in the Spanning Tree Protocol screen
and press the Enter key. A Spanning Tree Protocol Configuration screen sim-
ilar to the following will appear. The top half of this screen displays read-only
values. The bottom half, starting with Spanning Tree Protocol, is user config-
urable. Use the Up Arrow and Down Arrow keys to highlight a field, then
press Enter to change the value. When you finish, press the Esc key until