HTTP Configuration
The HTTP Configuration screen, shown in Figure 6-9, allows you to enable
or disable Web management.
Note: Port 80 is used for HTTP service.
Select Apply to make changes. Select OK to return to the previous panel.
Select Cancel to cancel any changes.
19
Instant EtherFast
Figure 6-9
Series
EtherFast
Layer 3 Management 4-Port Gigabit Ethernet Switch
®
®
Serial Port Configuration
The Serial Port Configuration screen, shown in Figure 6-10, allows you to
access the communication parameters for the Switch's serial port. (Linksys rec-
ommends that you do not change the default settings.)
• Baud Rate - The rate at which data is sent between devices. Default is 19200.
Options are 9600, 19200, and 38400 baud.
• Data Bits - Sets the data bits of the RS-232 port. Options are 7 and 8.
• Stop Bits - Sets the stop bits of the RS-232 port. Options are 1 and 2.
• Parity - Sets the parity of the RS-232 port. Default is None. Options are none,
odd, and even.
• Time-Out - If no input is received from the attached device after this inter-
val, the current session is automatically closed. Default is 10 minutes. The
range is 0 to 100 minutes, where 0 indicates disabled.
• Auto Refresh - Sets the interval before a console session will auto refresh the
console information, such as Spanning Tree Information, Port Configuration,
Port Statistics, and RMON Statistics. Default is 1 second. The range is 0, or
5 to 255 seconds, where 0 indicates disabled.
Select Apply to make changes. Select OK to return to the previous panel.
Select Cancel to cancel any changes.