Communications Methods
4) Selective Access (Trigger Mode only on Selective Access)
In the selective access trigger function, a selected Tag from among multiple Tags in the commu-
nications area of the Antenna is accessed. First, temporary numbers are assigned to the Tags in
the communications area. The Tag Selection Command allows the Controller to communicate
with a selected Tag according to each temporary number assigned.
a. Temporary number assigned
b. Communications with Tag No. 2
5-34
2
1
3
2
1
3
Section 5-5