7.1.2 Menu description
ICON
FUNCTION
Power
Ventilation*:
Temperature
Fuel
Time breaker switch
* Only for versions equipped with one or two hot air distribution fans
ICON
FUNCTION
SUBMENU
Adjustment
[10] Keyboard lock
[11] Screen brightness
[12] Display mode
[13] Sound signaller volume
[14] Pellet type
[15] Inactive function
[30] Fitter's menu
[40] Service menu
Submenu [30] and [40] and the Configuration menu are password protected and intended solely for the technical service.
* Only for versions equipped with one or two hot air distribution fans ** If available

7.2 USING THE CONTROL KEYBOARD

• Touching the arrow keys
menus, which are highlighted one by one.
• To change the settings of a given function, it is enough
to press the
button when the function is displayed
and change the value using the
Setting working power.
Setting of air fan power in room
Displays the room temperature and allows for programming the desired
temperature.
Displays the time of independent operation and enables zeroing of this time during
pellet loading [FULL] or deactivation of the display [OFF].
Activates and deactivates the time breaker switch. When the control clock is
engaged, the icon is displayed constantly.
Weekly scheduler
[1]
Programs
[2]
Clock/date
[3]
Hours remaining
[4]
System information
[5]
Inactive function
[6]
Eco function
[7]
Reignition delta
[8]
Anti-freeze protection
[9]
temperature
[31] Loading pellets**
[36] Pairing
[37] Pairing*
[38] Pairing*
scrolls through di erent
keys.
DESCRIPTION
DESCRIPTION
Assignment of programs (max. 3) to di erent days of
the week.
Configuration of programs.
Setting the date and time.
Displays the number of hours remaining until the next
recommended maintenance. The "Hi" value signifies a
number greater than 999 hours.
Displays the current software version.
Activates or deactivates Eco mode, which enables
automatic firing and extinguishing depending on ambient
temperature (only in configuration 1).
The di erence in degrees relative to room temperature,
below which the stove will reignite (only in configuration
1).
The minimum temperature below which the stove is fired
up (only in configuration 1).
Configuration of button locking
Sets the brightness level of the screen.
Configuration of data display.
Setting of the sound signaller's volume.
3 di erent pellet types can be set.
Changes/displays stove configuration.
Manual activation of the pellet loading system
Ambient temperature
Right fan - R
Left fan - L
Menu intended for technical service.
• Press the
• In general, all flashing parameters can be changed using
the
• The "Cancel" button
change; pressing it for a long time displays the code of
the alarm that may have been activated.
ENGLISH
VALUES
c : OFF,1..5 ; A ; Hi
r* : OFF, 1 ... 5
l* : OFF, 1 ... 5
from 6°C to 51°C
FULL – OFF
ON – OFF
VALUES
from [d1] to [d7]
from [P1] to [P6]
OFF; Eco
from 0,5°C to 5,0°C
from 3°C to 20°C
OFF; Lo; Hi
from 1 to 5
from 1 to 4
from 1 to 5
from 1 to 3
PWD: „54"
PWD: "54"
ON; OFF; t
ON; OFF; t
ON; OFF; t
key again to confirm the change.
keys.
makes it possible to cancel a
1–5
OFF;
OFF;
OFF;
OFF;
11