Service Information
Unit:
M 100 CD MK II
Possible complaint:
CD's are at times not read, tracks are not found.
Remedy:
Replacement of the microprocessor CIC 1 carrying the designation
D78P048 AGF M 100 CD with a D78P048 AGF CD-05 MK-II.
Workshop:
In the event of a complaint, replace the microprocessor along with new
software.
Stockkeeping:
CIC 1, D78P048 AGF CD-05 MK-II, part no. 59798 419 0000
46161(8002/8012, 8005/8015)
Returns
analysis
1/1