3.4.2

Technical data

Weight, net
Drum volume
Drum diameter
Drum depth
Drum speed, medium load
Rated capacity, filling factor 1:18 (Max. load)
Rated capacity, filling factor 1:22 (Recommended load)
Optimum air flow**
Optimum static back pressure**
Maximum static back pressure**
Sound power/pressure level at drying*
Average heat emission per drying cycle used to assess ventilation need***
Ambient operating temperature
* Sound power levels measured according to ISO 60704.
** In a cold empty machine.
*** For assistance with dimensioning necessary ventilation needs, contact authorized ventilation technician. For suffi-
cient ventilation all sources introducing heat need to be taken into account plus all other parameters effecting the
ventilation need. Climate zone, building parameters, room size, etc.
Connections
Pipe connection, condensed water
Heat pump
Type of refrigerant
Amount of refrigerant
Fluorinated greenhouse gases
This product contains fluorinated greenhouse gases:
R134a: 1.600 kg
GWP 1430
CO
equivalent 2.288 t
2
Hermetically sealed
Installation manual
17
kg
253
liters
255
mm
755
mm
595
rpm
43
kg
14.2
kg
11.6
3
m
/h
N/A
Pa
N/A
Pa
N/A
dB(A)
72/56
kW
1.2
+10 – +45
⌀ mm
15
R134a
kg
1.6