Download Print this page
Leviton Decora Mural MCX10-1 Installation Instructions
Leviton Decora Mural MCX10-1 Installation Instructions

Leviton Decora Mural MCX10-1 Installation Instructions

Scene capable dimmer 120vac, 60hz

Advertisement

Quick Links

C O L L E C T I O N B Y L E V I T O N
• Leviton's Decora
• Soft fade ON/OFF
• Minimum Brightness Adjustment
• Brightness Level Display
• Double Tap functions
Scene Capable Dimmer
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
120VAC, 60Hz
This device must not cause harmful interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.
Fluorescent Only
WARNING:
Cat. No. MCX1Ø-1, 1000VA
CODES AND REGULATIONS.
(w/brightness level display)
WARNING:
QUALIFIED ELECTRICIAN.
Total minimum wattage
WARNING:
must exceed 60VA
OTHER EQUIPMENT, USE ONLY WITH THE APPROPRIATE ADVANCE MARK X™ 120V ELECTRONIC
DIMMING BALLASTS FOR CONTROLLING THE SPECIFIC FLUORESCENT LAMPS.
For use w/ Advance
OTHER CAUTIONS:
Mark X™ Dimming Ballasts
1. BOTH LIGHTING FIXTURE AND DIMMER MUST BE GROUNDED.
2. DISCONNECT POWER WHEN SERVICING OR CHANGING LAMPS.
3. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY
INSTALLATION INSTRUCTIONS
MULTI-GANG INSTALLATION:
When ganging dimmers, the side sections of the mounting strap must be removed. Use pliers to carefully bend
side sections back and forth until they break off (refer to Figure 1). The side sections dissipate heat, so removing
them requires a derating of the dimmer's capacity (refer to chart).
MAXIMUM BULB WATTAGE:
DI-00X-MCX10-00A
Advance Mark X™ dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency
of the Advance Mark X™ ballast. Table 1 shows the maximum number of ballasts that can be connected to a
single dimmer for different Advance Mark X™ ballasts. Also note the table shows maximum ballasts for multi-
gang installations.
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
NOTE: For multiple ballasts on one dimmer, use only the same model ballast.
Leviton warrants to the original consumer purchaser and not
TO INSTALL:
for the benefit of anyone else that this product at the time of its
sale by Leviton is free of defects in materials and workmanship
1.
under normal and proper use for two years from the purchase
date. Leviton's only obligation is to correct such defects by repair
2. Remove existing wallplate and switch or dimmer, if applicable.
or replacement, at its option, if within such two year period the
product is returned prepaid, with proof of purchase date, and a
3. Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are straight.
description of the problem to Leviton Manufacturing Co., Inc.,
4. Connect lead wires per appropriate WIRING DIAGRAM as follows: Twist strands of each lead tightly and,
Att: Quality Assurance Department, 59-25 Little Neck
Parkway, Little Neck, New York 11362-2591 (In Canada send
to Leviton Mfg. of Canada Ltd., 165 Hymus Blvd., Point
Claire, (Quebec), Canada H9R 1E9). This warranty excludes
and there is disclaimed liability for labor for removal of this product
5. Carefully position all wires to provide room in outlet box for dimmer. Mount dimmer into box with mounting
or reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under
6. Restore power at circuit breaker or fuse. Turn the dimmer ON by pressing the upper half of the rocker. The
normal operating conditions or not in accordance with any labels
or instructions. There are no other or implied warranties of any
kind, including merchantability and fitness for a particular
NOTE: This model incorporates a trim adjustment which will allow the installer to precisely set the low end of the
purpose, but if any implied warranty is required by the applicable
dimming range to suit each installation. This adjustment is preset at the factory and should require no further
jurisdiction, the duration of any such implied warranty, including
adjustments for most installations. If adjustment is required proceed as follows, otherwise continue with step 9:
merchantability and fitness for a particular purpose, is limited to
7. The brightness adjustment is located on the side of the dimmer (refer to Figure 1). Using a small, insulated
two years. Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage
to, or loss of use of, any equipment, lost sales or profits or delay
or failure to perform this warranty obligation. The remedies
provided herein are the exclusive remedies under this warranty,
8. Release the rocker. Release adjustment switch and minimum brightness is set. Check for
whether based on contract, tort or otherwise.
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
9. Attach Decora
NOTE: On the lower left corner of the switch frame, there is an air-gap switch. When
servicing a controlled fixture, pull lever out (OFF position). This will cut the power to the
fixture. After servicing is complete, push the lever in (ON position) to restore power. The lever
DI-00X-MCX10-00A
must be pushed in all the way (ON position) for normal operation.
DI-00X-MCX10-00A
1
FEATURES
®
Style design
• Scene Capabilities
• Power interruption - load returns to existing state
• ON/OFF LED indicates status of load
• Color conversion available
FCC COMPLIANCE STATEMENT
INSTALLATION INSTRUCTIONS
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A
TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND
DEVICES MARKED CO/ALR OR CU/AL.
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE
AND TEST THAT POWER IS OFF BEFORE WIRING!
with circuit conductors, push firmly into appropriate wire connector (see chart for allowable wire
connector and number of conductor combinations). Screw connectors on clockwise making sure that no
bare conductor shows below the wire connectors. Secure each connector with electrical tape.
screws supplied.
GREEN LED will turn OFF to indicate power to the dimmer (when the dimmer is OFF, the LED is ON).
screwdriver, depress the brightness adjustment switch. To increase the minimum brightness, press the upper
half of the rocker.
To decrease the minimum brightness, press the lower half of the rocker.
proper operation by tapping the lower half of the rocker so the lights turn OFF, then
tapping the upper half of the rocker so the lights turn ON.
The lights will turn ON to the new minimum brightness set. If operation is not satisfactory,
repeat step 7.
®
wallplate (not included). INSTALLATION IS COMPLETE.
Figure 1 – Dimmer Functions
Mounting Strap
Side Sections
Upper
Rocker
Brightness Level
Display
Lower
Rocker
Air Gap
Switch
MAXIMUM LOAD PER DIMMER FOR MULTI-GANG
Cat. No.
Single
MCX1Ø-1
1000VA
TABLE 1
Cat. No. MCX1Ø-1, 120V – For use with
Advance Mark X™ 120V Dimming Ballasts
Advance
Mark X™
Lamps
Part No.
REZ-1T32
CFM26W/GX24Q
REZ-1T32
CFM32W/GX24Q
REZ-1T42
CFM42W/GX24Q
REZ-2Q26
CFQ26W/G24Q
F25T8
REZ-132
REZ-2S32
F25T8
F25T8
REZ-3S32
REZ-132
F32T8
F32T8
REZ-2S32
REZ-3S32
F32T8
FT40W/2G11
REZ-1TTS40
REZ-2TTS40
FT40W/2G11
WIRE CONNECTOR / # OF CONDUCTOR COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #14 w/ 1 #16 w/ 1 or 2 #18 or #20
2- #12 w/ 1 #14 w/ 1 #16 or #18
3- #14 w/ 1 or 2 #18 or #20
2- #12 w/ 1 #16 w/ 1 or 2 #18
4- #14 w/ 1 #16 or #18
2- #14 w/ 1 to 3 #16, #18 or #20
2- #16 w/ 1 #18 w/ 1 or 2 #20 or #22
4- #16 w/ 1 or 2 #18, #20 or #22
1- #14 w/ 1 #18 w/ 1 to 3 #20
1- #14 w/ 1 to 4 #16, #18 or #20
3- #14 w/ 1 #16 w/ 1 #18, #20, #22
2- #14 w/ 1 to 3 #16, #18 or #20
3- #14 w/ 1 #18 w/ 1 #20 or #22
10/4/02, 10:28 AM
Minimum Brightness
Adjustment Switch
ON/OFF
LED
Two
More than
Gang
2 Gang
800VA
700VA
Max. # Ballasts/Dimmer for Multi-gang
Single
More than
Two
Gang
Ganged
2 Gang
32
26
22
21
18
26
20
16
14
14
12
17
32
26
22
13
12
17
11
9
8
28
22
19
14
11
10
9
8
7
25
20
17
12
10
9

Advertisement

loading

Summary of Contents for Leviton Decora Mural MCX10-1

  • Page 1 TO INSTALL: for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE...
  • Page 2 COLOR CONVERSION PROCEDURE The color of this device can be changed to suit your interior design requirements. Simply obtain a color conversion kit of the appropriate color from your Leviton distributor and proceed as follows (please note that wallplate must be removed).