Removal of Four Way Valve
Step
24
Procedure
Points
Note:
Do not use a metal saw for
cutting pipes by all means
because the sawdust comes
into the circuit.
When withdrawing the pipes,
be careful not to pinch them
firmly with pliers. The pipes
may get deformed.
Provide a protective sheet or
a steel plate so that the
(R7250)
brazing flame cannot
influence peripheries.