Siemens SIMATIC MV320 Operating Instructions Manual page 28

Hide thumbs Also See for SIMATIC MV320:
Table of Contents

Advertisement

Technical data
Permitted ambient conditions
Degree of protection
Operating temperature
Storage temperature
Humidity
Impact resistance
Resistant to ambient light
Dimensions and weight
Dimensions (L x W x H)
Weight
Color
Read distances
The read distances are made up of a wide field and a near field.
• All code patterns must be of high quality and on a physical midline at an angle of 10°
when read.
• The table refers to the AGC factory settings; accuracy: ± 10 %
Table 8- 1
Test code
3 mil Code 39
7.5 mil Code 39
10.5 mil GS1 DataBar
13 mil Code 128
5 mil Data Matrix
6.3 mil Data Matrix
10 mil Data Matrix
20.8 mil Data Matrix
1 mil = 0.0254 mm
The ideal read distance is about 100 mm. Depending on the code type and code size, smaller
or larger distances are possible.
28
Read distances
Min. mm
85
18
5
13
28
18
5
13
IP54
-20 ... +55 °C
-30 ... +65 °C
5 ... 95%, no condensation
Resistant to being dropped repeatedly on con-
crete from a height of 1.8 m
Up to 96 890 lux
77 x 52 x 132 mm
116 g
Dark gray
Max. mm
107
167
205
265
100
135
165
328
SIMATIC MV320 (as of FS: A3)
Operating Instructions, 03/2021, C79000-G8976-C643-01
6GF3320-0HT01

Advertisement