LM22
Motor Rr
i
LM23
Motor Lm
i
LM - Motor Data Parameters
This is the per phase induction motor rotor resistance.
This parameter is not applicable to PM Synchronous motors and therefore
will not appear.
This value can be learned with a Motor Tune. Refer to Section 5.9 for
further details.
This is the per phase induction motor magnetizing inductance. The magnetizing
inductance can be monitored from Diagnostics Screen #1 or in parameter
DG09. If the actual magnetizing current is too high, lower this inductance value
in steps of 20. If it is too low, raise the value.
This parameter is not applicable to PM Synchronous motors and therefore
will not appear.
This value can be learned with a Motor Tune. Refer to Section 5.9 for
further details.