SECTION FOUR – Routine Maintenance and Professional Servicing

Ignition Control Module

L L L L o o o o c c c c a a a a t t t t i i i i o o o o n n n n
The Ignition Control Module is located in the Control
Box.
F F F F u u u u n n n n c c c c t t t t i i i i o o o o n n n n
The Ignition Control Module receives line voltage for
powering the Blower and Ignitor, and is sequenced by
low voltage supplied from the Operating Control Board
through the safety interlocks. It also supplies low-volt-
age power to the Combination Gas Valve.
S S S S e e e e r r r r v v v v i i i i c c c c i i i i n n n n g g g g P P P P r r r r o o o o c c c c e e e e d d d d u u u u r r r r e e e e
To access the Ignition Control Module:
1. Turn off the pump and all electrical power to the
heater.
2. Unbolt and remove Upper Left and Upper Right
Jackets from the heater.
3. Open the Control Box cover by loosening the screw
on the top right side of the cover.
4. Disconnect all wires to the Ignition Control Module.
5. Remove the Ignition Control Module and replace it
with a new one.
S S S S a a a a f f f f e e e e t t t t y y y y P P P P r r r r e e e e c c c c a a a a u u u u t t t t i i i i o o o o n n n n s s s s : : : :
Hazardous voltage. Both the Control Box
and the Ignition Control Module contain line voltage.
Disconnect the heater from the main power source
when servicing or replacing these parts.
Ignition Control Module
N T
V E
S
E S
P R
B
TA
O T
P IL
6. Reconnect all wires to the Ignition Control Module
according to the connection diagram, Page 4-31.
7. Replace all covers and restart heater.
ing, possible fire or explosion. Use
parts when replacing the Ignition Control Module.
4-5
P/N 42001-0052S
2687 1096
Risk of control malfunction, overheat-
only
Sta-Rite