STA-RITE SR200NA Service Manual page 24

Pool/spa heater
Table of Contents

Advertisement

SECTION TWO – Heater Installation
Heater Electrical Connections
F F F F i i i i r r r r e e e e m m m m a a a a n n n n ' ' ' ' s s s s S S S S w w w w i i i i t t t t c c c c h h h h / / / / R R R R e e e e m m m m o o o o t t t t e e e e
N N N N O O O O T T T T E E E E : : : : If, while there is line voltage connected to the
heater, you touch either line voltage terminal with any
24VAC wire that is connected to the control board
(including the Fireman's Switch jumper), you will imme-
diately destroy the control board and void the warranty.
If the filter pump is controlled by a time clock, a low-
voltage Fireman's Switch that switches off the heater
at least 15 minutes before shutting off the pump should
be installed. The Fireman's Switch completes the circuit
for the low voltage safety switches; it DOES NOT get
any power from the 115 volt power supply.
N N N N O O O O T T T T E E E E : : : : When using a timer and Fireman's Switch, the
heater's power supply should come from the load side
of the timer.
Connect the Fireman's switch to the heater as follows:
1. Turn off power to heater at main circuit breaker
panel.
2. Unbolt and separate the upper jacket halves.
3. Remove the Control Box Cover.
S S S S a a a a f f f f e e e e t t t t y y y y P P P P r r r r e e e e c c c c a a a a u u u u t t t t i i i i o o o o n n n n s s s s : : : :
Hazardous voltage. Can shock, burn, or
kill. Use all normal precautions for working with 120 or
240 VAC electrical power.
TRANS
OPERATING CONTROL
MEMBRANE PAD
BK
CONNECTION
JMP3
ENABLE TOGGLE
1
DISABLE TOGGLE
VERSION 1 PAD
CONTROL CENTER
SPA CONTROL
TRANS
F
I
S
R
W
E
I
L1
FL
T
M
A
C
N
H
S
F1
GND
JUNCTION BOX
24VAC
Figure 2-14A: Fireman's Switch/Remote
Connections – Single Voltage Heater
(See Figure 2-14)
BK
Y
Y
W
Y Y
TERMINAL BOARD
W
TRANS
TRANS
W
L2
W
BM
Time Clock or Remote
NEUTRAL
(Purchase Separately –
Supplies Power to
Circulator Pump)
Fireman's Switch
Completes the heater
24 Volt AC Control
Board Circuit.
DO NOT connect this
circuit to 115 Volt AC!
4. Remove the factory-installed jumper between the
Fireman's Switch terminals. See Figure 2-14.
5. Connect the wires between the Fireman's Switch
terminals on the heater and the Fireman's Switch
terminals on the time clock using 18 gauge (1 mm
wire with a minimum 3/64"(1.2 mm) thick insula-
tion rated for a temperature rise of at least 221° F
(105° C). Route the wires through the heater's junc-
tion box (See Figure 2-14). The fuse is a 1.25 amp
AGC 1-1/4"fast blow fuse, available locally.
6. Reinstall and bolt up the jacket halves.
M M M M a a a a x x x x i i i i m m m m u u u u m m m m T T T T e e e e m m m m p p p p e e e e r r r r a a a a t t t t u u u u r r r r e e e e S S S S e e e e t t t t P P P P o o o o i i i i n n n n t t t t
To set the Maximum Temperature Set Point, proceed as
follows:
1. Turn heater off.
2. Unbolt and remove upper jacket halves.
3. Depress clips and remove control board assembly
dome.
4. Push the Maximum Temperature Set Point button
on the back of the control board (See Figure 2-15).
The following sequence should happen:
A. The unit will come on and the POOL ON light
will come on.
B. Press the appropriate TEMP
(on TOP of the panel) to set maximum pool
temperature.
TRANS
OPERATING CONTROL
BK
O
ENABLE TOGGLE
DISABLE TOGGLE
CONTROL CENTER
TERMINAL BOARD
L1
F1
L1
Figure 2-14B: Fireman's Switch/Remote
Connections – Dual-Voltage Heater
2-15
or TEMP
BK
O
Y
Y
Y Y
24VAC
J6
MEMBRANE PAD
CONNECTION
VERSION 1 PAD
SPA CONTROL
W
W
TRANS
F
I
S
R
W
W
E
I
L2
FL
T
M
A
C
N
H
R
S
BM
R
L2
GND
Time Clock or Remote
(Purchase Separately —
Supplies Power to
Circulator Pump)
Fireman's Switch
Completes the heater
24 Volt AC Control
Board Circuit.
DO NOT connect this
circuit to Line Voltage!
24VAC
)
2
pad

Hide quick links:

Advertisement

Table of Contents
loading