Heater Water Connections
P P P P r r r r e e e e s s s s s s s s u u u u r r r r e e e e S S S S w w w w i i i i t t t t c c c c h h h h S S S S e e e e t t t t t t t t i i i i n n n n g g g g s s s s : : : :
The water Pressure Switch turns off the burner if the
water flow is interrupted. If the water flow is restricted,
the water Pressure Switch may prevent the burner from
firing and cause the "Service System" light to come on.
For deck-level heater installations, the Pressure Switch
is factory-set at 3 psi.
If the Pressure Switch is 2 to 4 feet
level, turn the star-wheel on the switch clockwise
to raise the pressure setting. See Figure 2-17, below.
If the Pressure Switch is 2 to 5 feet
level, turn the star-wheel on the switch
-clockwise
to lower the pressure setting.
counter
(
)
See Figure 2-17, below.
N N N N O O O O T T T T E E E E : : : : When the Pressure Switch is more than 4 feet
below the pool water level, or more than 5 feet above the
pool water level, a Flow Switch is required. The Pressure
Switch is no longer adequate for the installation.
Raise Pressure
Turn star wheel to
raise pressure set
point if pressure
switch is more than
2 feet (.6 M) below
water level
Lower Pressure
Turn star wheel
to lower pressure
set point if pressure
switch is more than
5 feet (1.5 M) above
water level
Back of pressure switch
has a reference scale.
Figure 2-17: Pressure Switch Adjustment
the pool water
below
(
)
the pool water
above
2734 1296
2-17
W W W W a a a a t t t t e e e e r r r r P P P P i i i i p p p p i i i i n n n n g g g g S S S S p p p p e e e e c c c c i i i i f f f f i i i i c c c c a a a a t t t t i i i i o o o o n n n n s s s s
The heater is designed to be connected directly to
2-inch PVC pipe, using the integral unions provided.
The low thermal mass of the heater prevents overheat-
ing of the piping if the pump stops. There is no need
for a heat sink.
Improper operation of chemical feeders
can cause severe damage to the heater, which is not
covered by the warranty. Install the chemical feeder
downstream of the heater. Equip the chemical feeder
with an anti-syphon device to prevent chemicals from
siphoning into the heater if the pump stops.
W W W W a a a a t t t t e e e e r r r r F F F F l l l l o o o o w w w w R R R R a a a a t t t t e e e e R R R R e e e e q q q q u u u u i i i i r r r r e e e e m m m m e e e e n n n n t t t t s s s s
Maximum and minimum water flow rates required by
the heater are listed below:
Table 2-M: Maximum/Minimum Flow Rate
Maximum and Minimum
Flow Rate in GPM (LPM)
Model
Minimum Flow
200
20 (76 LPM)
333
33 (114 LPM)
400
40 (151 LPM)
Maximum Flow
120 (454 LPM)
120 (454 LPM)
120 (454 LPM)