Siemens SIMATIC ET 200SP Equipment Manual page 32

Cm ptp communications module
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Parameters/address space
4.3 Parameter setting
Read message length from
message
Offset of length field in
message
Size of length field
Number of characters not
counted in length specifi-
cation
After receipt of an end
sequence
Buffered received frames
Prevent overwriting
Clear receive buffer on
startup
Priority
With block check (3964R)
Use default values
Connection attempts
Transmission attempts
Character delay time
Acknowledgment delay
Due to the limited number of parameters at a maximum of 244 bytes per station with a PROFIBUS
1
GSD configuration, the configuration options are restricted. This parameter is visible. The other pa-
rameters are preassigned in the module with the default setting. If your PROFIBUS master supports
the "Read/write data record" function, you can set the other parameters using the respective data
records.
When configuring with GSD file, you specify the option by selecting the module name.
2
32
Parameter
Deactivated
Activated
0...2047 bytes
1 byte
2 bytes
4 bytes
0...255 bytes
Deactivated
Activated
1...255
Deactivated
Activated
Deactivated
Activated
High
Low
Deactivated
Activated
Deactivated
Activated
1...6...255
1...6...255
20...220...65535 ms
20...2000...65535 ms
Value range
CM PtP communications module (6ES7137-6AA01-0BA0)
Equipment Manual, 03/2021, A5E03790792-01
Scope
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6es7137-6aa01-0ba0

Table of Contents