General Service Lives Of Oils; Description Of Maintenance And Repair Works; Test The Water Content Of The Oil; Change Oil - Siemens FLENDER GHZP Assembly And Operating Instructions Manual

Table of Contents

Advertisement

10.1.1 General service lives of oils

According to the oil manufacturers, the following are the expected periods during which the oils can be
used without undergoing any significant change in quality. They are calculated on the basis of an average
oil temperature of 80 °C:
─ for mineral oils, biologically degradable oils and physiologically safe (synthetic esters) oils 2 years
or 10 000 operating hours (does not apply to natural esters, such as rape seed oils).
─ for poly­α­olefins and polyglycols, 4 years or 20 000 operating hours.
The actual service lives may differ. The general rule is that an increase in temperature of 10 K
will halve the service life and a temperature decrease of 10 K will approximately double the
service life.
10.2

Description of maintenance and repair works

10.2.1 Test the water content of the oil

More information about examining the oil for water content or conducting oil analyses is obtainable from
your lubricant manufacturer or our customer service.
For reference purposes, a fresh sample of the operating lubricating oil used must be sent with the used
oil sample to the analysing institute for analysis.
The oil sample must be taken downstream of the filter of the oil­supply system while the gear unit is
running. A suitable connection point is normally located upstream of the gear­unit input (e.g. oil­drain
cock in the pressure line).
A special sample container should be filled with the specified quantity of oil.
If there is no such sample container available, at least one litre of oil must be put in a clean,
transportworthy, sealable vessel.

10.2.2 Change oil

As an alternative to the oil­change intervals indicated in table 11 (see item 10.1) it is possible to have an
oil sample tested at regular intervals by the Technical Service of the relevant oil company and to have it
released for further use.
If further usability has been confirmed, no oil change will be necessary.
Please observe the separately attached BA 7300 instructions manual.
The instructions in item 7.1 must be observed!
Drain the oil while the gear unit is still warm, i.e. immediately after shutting down the machinery.
Please observe the notes in the operator information for the separate oil­supply system.
BA 5814 en 09/2014
55 / 61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flender ghdp

Table of Contents